COMMERCIAL STACK DRYER SPECIFICATIONS
STACK DRYER SPECIFICATIONS
MODEL NUMBER
GENERAL INFORMATION
Stainless Steel Look Push Button console, powdered paint
cabinet, improved collar assembly featuring cam lock console,
taller profile and improved security meter case integral with
collar, 2 coinbox and money acceptor openings, T40 Torx & Pin
security included, removable indoor lint filters. Upper and
lower dryers may use different money acceptors at the same
time. 3 way venting upper dryer, 4 way lower.
ELECTRICAL REQUIREMENTS
(2 connections required per stack unit)
MOTOR
HEATER TYPE
HEATER/BURNER RATING
(Add 500 watts approx. for motor on all dryer models)
AMPERAGE
(Does not include control or gas valve)
DIMENSIONS
SHIPPING WEIGHT (EST.)
DRUM VOLUME
* Burner orifices are available for manufactured, natural, mixed and LP gas with varying BTU ratings
** LP Conversion Kit: 49572 (Two per stack dryer required)
***
Power cords on electric models sold separately
STACK DRYER
FRONT VIEW
To locate a distributor near you, please visit www.whirlpoolcommerciallaundry.com/distributor, or call 1-800-NO-BELTS
CSP2760TQ
***
Dual Metercase
Accepts the Following
Payment Systems:
Coin Slide
Retrofit Coin Drop
Retrofit Card Reader
OPL
Push-to-Start
3 or 4-Wire Nominal
240/208-Volt, 60 Hz, A.C.
Standard 30 Amps
Breaker/Fuse Branch
Circuit per Dryer Drum
(Subject to Local Codes)
Two
-HP Motors
1
3
with Built-In Overload
Protector 5.9 Amps
Max Rating
ELECTRIC
2 Electric Heaters Rated
at 5600 Watts per Dryer
(11.2 KW Total)
Motor — 4.0 Amps
No Load per Motor
8 Amps Total
Heater
23.33 Amps @ 240V x 2,
54.66 Total
76.75" H, 27" W, 28.5" D
294 Lbs.
14.8 Cu. Ft.
(7.4 Cu. Ft. per Drum)
STACK DRYER
RIGHT/LEFT VIEW
CSP2761TQ
**
Dual Metercase
Accepts the Following
Payment Systems:
Coin Slide
Retrofit Coin Drop
Retrofit Card Reader
OPL
Push-to-Start
Nominal, 120-Volt, 60Hz.,
A.C. 15 Amp Breaker/Fuse
Branch Circuit per Dryer Drum
Two
-HP Motors
1
3
with Built-In Overload
Protector 5.9 Amps
Max Rating
GAS
*
2 Burner Assemblies Rated
at 22,000 BTU per Dryer
(44 KBTU Total)
Natural Gas
Motor — 4.0 Amps
No Load per Motor
8 Amps Total
76.75" H*, 27" W, 28.5" D
300 Lbs.
14.8 Cu. Ft.
(7.4 Cu. Ft. per Drum)
EXHAUST INFORMATION
All dryers require the equivalent of a 4-inch
diameter exhaust duct. Rigid metal duct is
recommended. Failure to properly exhaust
the dryer will result in improper operation.
27" & 29" Dryer Venting Requirements
of 90°
#
Turns
4" Hood 2
" Hood
1
2
Maximum Length of 4" Diameter Rigid
Metal Duct
0
64 Ft.
58 Ft.
1
54 Ft.
48 Ft.
2
44 Ft.
38 Ft.
3
35 Ft.
29 Ft.
4
27 Ft.
21 Ft.
Maximum Length of 4" Diameter Flexible
Metal Duct
0
36 Ft.
28 Ft.
1
31 Ft.
23 Ft.
2
27 Ft.
19 Ft.
3
25 Ft.
17 Ft.
4
23 Ft.
15 Ft.
Dimensions are for planning purposes only.
For complete information, see installation
instructions packed with product.
STACK DRYER
BACK VIEW
CWLL112A