CYCLE STATUS INDICATORS
Appearance may vary.
The Cycle Status Indicators show the progress of a cycle.
–/+ (Adjust drying time indicators)
The –/+ indicators will light when a Manual Cycle has been
selected.
Check Vent
This indicator will show the status of airflow through the
dryer for the dryer's life. During the sensing phase at the
beginning of the cycle, the Check Vent light will come on if a
blocked vent or low airflow issue is detected. This light will
stay on for the entire cycle, but will turn off at the end of the
cycle. This feature is available during Automatic and Steam
cycles only. For more information on maintaining good
airflow, see "Check Your Vent System for Good Airflow."
NOTE: If there are other error issues during a cycle, the
Check Vent indicator will not light up. See "Troubleshooting"
section.
Eco Monitor (on some models)
The Eco Monitor allows you to see how the settings you
select affect your energy usage within the cycle chosen.
The Eco Monitor indicator may change, depending on the
options and modifiers selected.
Wet
The load is still wet and/or the cycle just started.
Damp (on some models)
This indicator shows that the load is partially dried and items
that you may wish to hang up or iron while still damp may
be removed.
Cool Down
The dryer has finished drying with heat, and is now tumbling
the load without heat to cool it down and reduce wrinkling.
Done
This will indicate that the selected cycle has ended and
the load may be removed from the dryer. If Wrinkle Shield
option has been selected, the dryer may continue to tumble
the load, even if the Done indicator is lit.
Sensing (on some models)
The Sensing indicator will light to indicate that the moisture
sensor on the dryer is operating.
Steaming (on some models)
This indicator will light when the Steam function is active.
NOTE: Steam is not available on all models or on all cycles.
Wrinkle Shield
Option (on some models)
™
This indicator will light if the Wrinkle Shield
selected and is running. The dryer will periodically tumble
the load for up to 140 minutes after the cycle has ended.
12
ADDITIONAL FEATURES
To obtain a drying rack for your dryer, order by calling
1-877-944-7566. You will need your model and serial
number and the purchase date. Remove and discard
any packing material before use.
Use the Drying Rack for items that you do not want to
tumble dry, such as sweaters and tennis shoes. When you
use the drying rack, the drum continues to turn, but the rack
remains stationary.
The drying rack is intended for use with the Manual Dry/
Timed Dry cycles only. The drying rack cannot be used
with Automatic cycles.
To use the drying rack:
IMPORTANT: Do not remove the lint screen.
1. Open dryer door.
2. Align the two hooks on the front of the drying rack with
™
3. Place wet items on top of the drying rack. Allow space
4. Close the door.
5. Select a Timed Dry/Air Only, or Low Temperature cycle.
6. When the cycle is selected, the Estimated Time
option has been
™
7. Start the dryer.
NOTE: Check the lint screen and remove any lint
accumulated from items dried on the drying rack
after the cycle is finished.
USING THE DRYING RACK
the holes in the dryer door opening and press down fully
into holes. Rest the rear support on the dryer back ledge.
around items for air to circulate. The drying rack does
not move, but the drum will rotate; be sure to leave
adequate clearance between items and the inside of
the dryer drum. Make sure items do not hang over the
edges or between drying rack grille.
Items containing foam, rubber, or plastic must be dried
on a clothesline or by using the Air Only setting.
Remaining display shows the default time. You can
change the actual time in the cycle by increasing or
decreasing the cycle time.