Whirlpool 2510498 Installation Instructions And Use & Care Manual - Page 9
Browse online or download pdf Installation Instructions And Use & Care Manual for Ventilation Hood Whirlpool 2510498. Whirlpool 2510498 28 pages. Wall-mount canopy range hood
Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover (Unscrew "C").
3. Remove the knockout in the terminal box cover and install a
UL listed or CSA approved 1/2" (1.3 cm) strain relief.
A
A. Knockout
B. Terminal box cover
C. Screws (7)
4. Run home power supply cable through strain relief into
terminal box.
A
C
D
E
A. Home power supply cable
B. UL listed or CSA approved
strain relief
C. Black wires
5. Use UL listed wire connectors and connect black wires (C)
together.
B
C
B
F
D. UL listed wire connectors
E. White wires
F. Green (or bare) and yellow green
ground wires
6. Use UL listed wire connectors and connect white wires (E)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box using
UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check that all light bulbs are secure in their sockets.
11. Reconnect power.
Install Vent Covers
When using both upper and lower vent covers, push lower
cover down onto hood and lift upper cover to ceiling. Install with
(2) 4.2 x 8 mm T20
screws using a T20
®
adapter provided) to tighten.
NOTE: For vented installations, upper vent cover may be
reversed to hide slots.
A
B
A. 4.2 x 8 mm screws
B. Bracket
Torx
drive (or T20
®
®
®
C
D
C. Upper vent cover
D. Lower vent cover
9