Whirlpool 30" (76.2 cm) Cooktop Installation And Use Manual - Page 6

Browse online or download pdf Installation And Use Manual for Ventilation Hood Whirlpool 30" (76.2 cm) Cooktop. Whirlpool 30" (76.2 cm) Cooktop 24 pages. 30" (76.2 cm) wall-mount canopy range hood
Also for Whirlpool 30" (76.2 cm) Cooktop: Use & Care Manual (16 pages), Manual (28 pages)

Whirlpool 30
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
6" (15.2 cm) Vent System
Vent Piece
45° elbow
90° elbow
6" (15.2 cm)
wall cap
3 " x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm)
3 " x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) 90° elbow
Example vent system
90˚ elbows
3¼" x 10"
(8.3 x 25.4 cm)
to 6" (15.2 cm)
transition
Maximum Recommended Length
1 - transition
2 - 90° elbows
1 - wall cap
8 ft (2.4 m) straight
Length of 6" (15.2 cm) system
6
6" (15.2 cm) Round
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
0.0 ft
(0.0 m)
4.5 ft
(1.4 m)
5.0 ft
(1.5 m)
6 ft
Wall cap
(1.8 m)
2 ft (0.6 m)
= 26 ft (7.9 m)
= 4.5 ft (1.4 m)
= 10.0 ft (3.0 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 22.5 ft (6.9 m)
" x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece
3 " x 10" (8.3 cm x 25.4 cm)
90° elbow
3 " x 10" (8.3 cm x 25.4 cm)
flat elbow
3 " x 10" (8.3 cm x 25.4 cm)
wall cap
Example vent system
3 " x 10"
(8.3 x 25.4 cm)
elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Maximum Recommended Length
1 - 90° elbow
8 ft (2.4 m) straight
1 - wall cap
Length of 3 " x 10" (8.3 cm x 25.4 cm)
system
" x 10" (8.3 cm x 25.4 cm)
5.0 ft
(1.5 m)
12.0 ft
(3.7 m)
0.0 ft
(0.0 m)
Wall cap
= 26 ft (7.9 m)
= 5.0 ft (1.5 m)
= 8.0 ft (2.4 m)
= 0.0 ft (0.0 m)
= 13.0 ft (3.9 m)