16
W Lift range
hood into final
position,
feeding
electrical
wire through
wiring opening.
Position the range hood so
that the large end of the keyhole
slots are
over the screws, Then push the hood
toward
the wall so that the screws are in the
neck of the slots. Tighten
mounting
screws
to cabinet,
making
sure mounting
screws
are in narrow
neck of slots. Make sure that
damper
blade,
if used, rotates up and
down
freely.
screw
17
W Connect
the white and black
wires of the power
supply cable
to the
white and black leads in the hood with
twist-on
connectors.
Connect
the power supply grounding
wire
to the green, grounding
wire inside the
range terminal
box with a twist-on
wire
connector.
Use caulking
to seal wire opening.
Replace
terminal
box cover.
18
n
Pull firmlv on tab to remove
filter/light
lens from range hood. Turn
filter/light
lens so that charcoal
filter pad is
facing
up. Lift tabs and remove
charcoal
filter pad. Discard charcoal
filter pad. Place
edge of filter/light
lens in opening
so that
right side is above
flange
and tab faces
downward.
Press filter/light
lens into position.
Non-vented
installation
W Put on safety glasses and gloves.
2
1 Check
vent baffle on top of range
hood.
"Non-vented"
should be facing
up.
3
n
Remove
knockout
from the wiring
opening
(rear or top) to be used.
Do Not remove
venting
knockouts.
5.1516.
-
4
H Remove
terminal
box cover on
range hood.
Injury Hazard
More than one person is required
to help
with installation
because of the weight
and size of range hood.
Failure to follow this instruction
could
result in serious
injury.
keyhole
slot
5
n
Lift range hood into final position
and center.
Mark on underside
of cabinet
the location
for the four keyhole
mounting
slots. Set range hood aside on a protected
surface.
6
H Determine
and clearly
mark a
vertical
centerline
in the cabinet
opening.
centerline
7
n
TO wire through
top, mark a line
7-l /2" from the right of the centerline
on the
underside
of the cabinet.
Mark the point on
this line that is l-3/8" from the back wall. Drill
a l-l /4" diameter
hole through
cabinet
at
this point.
centerline
To wire through
rear, mark a line 7-l /2" from
the right of the centerline
on the wall. Mark
the point on this line that is 64-5J8" from the
floor (or l-3/8" from underside
of cabinet).
Drill a l-l /4" diameter
hole through
wall at
this point.
8
n
Complete
Steps 14-l 7. Do Not
complete
Step 18. The charcoal
filter pad is
needed
in non-vented
installation.
/Li!fs!fiiJ!L~
Keep Installation
lnstruchons
( Congratulations!
)
reference.
The instructions
will
make reinstalling
your Whirlpool
range hood in another
home
as easy as the first
installation.
Panel D