Whirlpool AKR 773 IX Installation Datasheet - Page 8

Browse online or download pdf Installation Datasheet for Ventilation Hood Whirlpool AKR 773 IX. Whirlpool AKR 773 IX 29 pages.

Whirlpool AKR 773 IX Installation Datasheet

PRODUCT SHEET

1. Control panel.

2. Grease filters (1 or 2 pieces).
3. Lighting unit (in some models: halogen lamps).
4. Grease filter support trim.
Grease filter
Once a month wash the grease filter by hand or in a
dishwasher at low temperature and with quick cycle.
Important! The metal filter may become opaque over time;
this does not affect its filtering capacity.
To remove or wash the grease filter:
1. Disconnect the hood from the power supply.
2. Remove the dirty grease filter by pulling the handle
backwards and then downwards (Fig. 1).
3. After washing the grease filter proceed in reverse order to
refit it, making sure the entire extraction surface is
covered.
Replacing lamps
1. Disconnect the hood from the power supply.
2. Remove the grease filter (Fig. 1) and the grease filter
support trim (Fig. 2 - sequence a-b).
3. Remove the lamp to be replaced.
4. Only use 40 W max. E14 lamps.
For models with halogen lamps, use 20 W halogen lamps
(GU5.3-12V-Ø 50 mm).
5. Refit the grease filter support trim.
Fitting or changing the carbon filter
(filter hood models only):
Change the carbon filter every four months.
It cannot be washed or regenerated.
Fitting or changing the carbon filter:
1. Disconnect the hood from the power supply.
2. Remove the grease filter (Fig. 1) and the grease filter
support trim (Fig. 2 - sequence a-b).
3. If the carbon filters are already fitted (one or two filters,
depending on the your model, covering the motor
protection grilles) and need changing, turn the middle
handle (Fig. 3 - c) anticlockwise until they are released.
4. If the carbon filters are not fitted, fit them to cover the
motor protection grilles (two protection grilles - two
carbon filters, one protection grille - one carbon filter),
then turn the middle handle (Fig. 3 - c) of the filters
clockwise.
5. Refit the trim and the grease filter.
5019 318 33263
D
GB
F
NL
CONTROL PANEL
Light switch.
The light key has two positions
(lights Off - lights On).
To switch on the lights: move the key to the right.
Speed selector switch.
The motor key has several positions for controlling
extraction speeds according to the amount of steam and
fumes.
To increase the extraction power (speed): move the key
to the right.
Fig. 1
Fig. 2
Fig. 3
Models with halogen lamps
E
P
I
GR