Whirlpool AKR 995 Installation Datasheet - Page 28
Browse online or download pdf Installation Datasheet for Ventilation Hood Whirlpool AKR 995. Whirlpool AKR 995 28 pages.
31833160.fm Page 28 Friday, April 1, 2005 6:48 PM
AKR 631-666-812-966
AKR 943-948-952-995-996
Important - upon initial installation:
Selecting the hob type: to ensure accurate
"reading" by the sensors, the latter must be calibrated
to suit the type of hob as follows: with the hood OFF,
press buttons 3 and 4 at the same time until either
LED F for gas hobs, LED G for induction hobs or
LED H for electric hobs lights up.
Automatic and manual sensor calibration: the
hood automatically "calibrates" sensor operation, but
under certain circumstances (e.g.: in the event of a
prolonged power failure or upon initial installation)
calibration can be carried out manually, with the hood
OFF, by pressing buttons 5 and 6 at the same time for
more than 3 seconds, otherwise you can wait until the
hood carries out calibration automatically.
Maintenance
ALWAYS disconnect the hood from the mains before
performing maintenance.
Wash the grease filter and the carbon filter in a
dishwasher once a month, at the highest possible
temperature, using normal dishwasher detergent. It is
recommended to wash the filters on the their own.
After washing, reactivate the carbon filter by drying
it in the oven at 100 °C for 10 minutes. Fit a new
carbon filter every 3 years.
Remove the grease filters - Fig. 1: push the spring
release handle backwards (f1) then remove the filter
downwards (f2).
Clean the perimeter extraction panel
(if provided) as often as the grease filter, using a
cloth and a mild liquid detergent.
Never use abrasive substances.
Clean the sensor plate regularly.
Replacing bulbs
Use a small screwdriver or any other suitable tool
1.
to prise off (m-Fig. 1) the lamp cover (p-Fig.1).
Remove the burnt-out bulb.
2.
Use max 20 W halogen bulbs only, taking care not
to touch them with your hands.
Close the lighting unit (snap-on).
3.
Fitting the carbon filter:
Remove the grease filter (f1/f2 - Fig. 1).
1.
Remove the filter holder by turning the knobs
2.
(g - Fig. 2) through.
Fit the carbon filter (i - Fig. 2) in the filter holder
3.
(h - Fig.2).
Reverse the above procedure to re-fit the filter holder
and grease filter.
5019 318 33160
Fig. 1
* Only present on some models
PL
CZ
SK
H RUS BG
Fig. 2
RO
GB