Whirlpool GXI6536DXS1 Installation Instructions And Use & Care Manual - Page 4

Browse online or download pdf Installation Instructions And Use & Care Manual for Ventilation Hood Whirlpool GXI6536DXS1. Whirlpool GXI6536DXS1 28 pages. 36" (91.4 cm) island-mount canopy range hood

Whirlpool GXI6536DXS1 Installation Instructions And Use & Care Manual
INSTALLATION REQUIREMENTS
4 - Plastic vent clips
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
Level
Mounting template
Upper horizontal support bracket
Horizontal support
8- Vertical supports
2-Vent cover supports
Drill with 11¼"(3.0 cm), 3/8"(9.5 mm), %4" (2.75 mm) and
1/8"(3.0 mm) drill bits
Pilot hole drill bits (determined by chimney support
attachment
method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof
caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Parts needed
Home power supply cable
2 - 1/2"(12.7 mm) UL listed or CSA approved strain reliefs
3 UL listed wire connectors
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented
(recirculating)
installations,
you will also
need:
Recirculating
Kit Part Number W10294734 for non-vented
(recirculating)
installations only. See "Assistance
or Service"
section to order.
6" (15.2 cm) round metal vent duct. Length required is
determined by ceiling height.
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood ventilator assembly with vent transition, back draft
damper, and light bulb installed.
Canopy glass
2 - Retainer brackets for hood glass canopy.
2 - Rubber seals (canopy glass)
Metal grease filter
68-4x8mmscrews
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility
to comply with installation clearances
specified on the model/serial rating plate. The model/serial
rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions
provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements"
section.
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 80 Ibs (36.6 kg).
The range hood is factory set for venting through the roof or wall.
For non-vented (recirculating)
Installation see "Non-vented
(recirculating) Installations"
in "Connect Vent System" section.
Recirculating
Kit Part Number W10294734 is available from your
dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured
Home Construction
Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction
and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured
Home
Installation 1982 (Manufactured
Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
4-5x45mmscrews
T-10 Torx _ adapter
T-20 Torx _* adapter
4-Vent
covers
I"®TORX is a registered trademark
of Acument
Intellectual
Properties, LLC