Whirlpool LI3Y5B Installation Instructions And Use & Care Manual - Page 6
Browse online or download pdf Installation Instructions And Use & Care Manual for Ventilation Hood Whirlpool LI3Y5B. Whirlpool LI3Y5B 28 pages. 30 inch (76.2 cm) range hood
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
6" (15.2 cm) or Larger Round Vent System
Vent Piece
45° elbow
90° elbow
6" (15.2 cm) or larger
wall cap
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) or larger
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) or larger
90° elbow
Example vent system
90˚ elbow
2 ft (0.6 m)
Maximum Recommended Length
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of 7" (17.8 cm) system
6
Round
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
0.0 ft
(0.0 m)
4.5 ft
(1.4 m)
5.0 ft
(1.5 m)
Wall cap
6 ft (1.8 m)
= 50 ft (15.2 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)
3
" x 10" (8.3 cm x 25.4 cm) Vent System
¼
Vent Piece
3¼" x 10" (8.3 cm x 25.4 cm)
90° elbow
3¼" x 10" (8.3 cm x 25.4 cm)
flat elbow
3¼" x 10" (8.3 cm x 25.4 cm)
wall cap
Example vent system
3
" x 10"
¹⁄₄
(8.3 x 25.4 cm)
elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Maximum Recommended Length
1 - 90° elbow
8 ft (2.4 m) straight
1 - wall cap
Length of 3¼" x 10" (8.3 cm x 25.4 cm)
system
5.0 ft
(1.5 m)
12.0 ft
(3.7 m)
0.0 ft
(0.0 m)
Wall cap
= 35 ft (10.7 m)
= 5.0 ft (1.5 m)
= 8.0 ft (2.4 m)
= 0.0 ft (0.0 m)
= 13.0 ft (3.9 m)