Whirlpool UXD8630DYS Installation Use & Care Instructions - Page 5
Browse online or download pdf Installation Use & Care Instructions for Ventilation Hood Whirlpool UXD8630DYS. Whirlpool UXD8630DYS 40 pages. 30 76.2 cm and 36 91.4 cm retractable pop-up downdraft vent system
Also for Whirlpool UXD8630DYS: Installation Instructions And Use & Care Manual (36 pages), Installation Instructions And Use & Care Manual (44 pages)
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools Needed
Jigsaw or keyhole saw
■
Drill
■
1/8" (3 mm) drill bit for pilot holes
■
Pencil
■
Tape measure or ruler
■
Flat-blade screwdriver
■
Phillips screwdriver
■
3/8" (9.5 mm) nut driver
■
Level
■
Pliers
■
Metal snips
■
Wire stripper or utility knife
■
Caulking gun and weatherproof caulking compound
■
Parts Supplied
Top trim – stainless
■
End caps (2)
■
Lower support legs (2)
■
Undercounter mounting brackets (2)
■
4 x 8 mm screws (16)
■
3.5 x 9.5 mm screws (3)
■
3
/
" x 10" (8.3 cm x 25.4 cm) rectangular damper
1
■
4
5
/
" (13.4 cm) motor box
1
■
4
1/4" (6.4 mm) deep cover
■
Flat vent cover plate
■
6" (15.2 cm) diameter vent transition with damper
■
Parts Needed
UL listed or CSA approved 1/2" (1.3 cm) conduit connector
■
Wall or roof cap with damper to match vent system
■
Vent system
■
Home power supply cable
■
UL listed wire connectors (3)
■
Vent clamps/duct tape as required
■
INSTALLATION REQUIREMENTS
Location Requirements
NOTE: Downdraft vent is installed directly behind the cooktop.
Install the downdraft vent first, and then install the cooktop.
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the downdraft vent. It
■
is the installer's responsibility to comply with installation
clearances specified on the model/serial/rating plate. The
model/serial/rating plate is located on the front of the
downdraft vent above the terminal box cover.
Downdraft vent location should be away from strong draft
■
areas, such as windows, doors, and strong heating vents or
fans.
Cabinet opening dimensions that are shown must be used.
■
Given dimensions provide minimum clearance.
Consult the cooktop manufacturer installation instructions
■
before making any cutouts.
Check that the downdraft vent and cooktop location will
clear the cabinet walls, backsplash, and rear wall studs
inside the cabinet.
Check for the minimum distance between the front edge
of the countertop and the front edge of the cooktop. The
minimum horizontal distance between the overhead cabinets
is the same as the width of the installed downdraft vent.
All openings in ceiling and wall where the downdraft vent will
■
be installed must be sealed.
Grounded electrical outlet is required. See the "Electrical
■
Requirements" section.
When installing the downdraft vent, the cabinet drawer
■
will need to be removed and the drawer front installed
permanently to the cabinet.
Cabinet Construction:
Downdraft vent is designed for use in a cabinet with a depth of
24" (61 cm). Some installations require a countertop deeper than
25" (63.5 cm). See the "Countertop Cutout Dimensions" section.
The maximum depth of the overhead cabinet is 13" (33 cm).
Overhead cabinets installed at either side of the downdraft vent
must be 18" (45.7 cm) above the cooking surface.
For Mobile Home Installations
The installation of this downdraft vent must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A — or latest edition — or
with local codes.
5