Whirlpool UXD8636DYS Installation Use & Care Instructions - Page 14
Browse online or download pdf Installation Use & Care Instructions for Ventilation Hood Whirlpool UXD8636DYS. Whirlpool UXD8636DYS 40 pages. 30 76.2 cm and 36 91.4 cm retractable pop-up downdraft vent system
Also for Whirlpool UXD8636DYS: Installation Instructions And Use & Care Manual (36 pages)
NOTE: The downdraft vent system is supplied with a 3
(8.3 cm x 25.4 cm) backdraft damper and a 6" (15.2 cm) round
vent transition with damper. Refer to "3
(8.3 cm x 25.4 cm) Backdraft Damper" or "6" (15.2 cm) Round
Vent Transition with Damper," depending upon the type of venting
you are using.
3
/
" x 10" (8.3 cm x 25.4 cm) Backdraft Damper
1
4
1. Attach the 3¼" x 10" (8.3 cm x 25.4 cm) backdraft damper
to the vent opening in the blower motor box, using three
3.5 x 9.5 mm screws.
B
A. 3.5 x 9.5 mm screws
B. 3¼" x 10" (8.3 cm x 25.4 cm) backdraft damper
6" (15.2 cm) Round Vent Transition with Damper
1. Attach the 6" (15.2 cm) round vent transition to vent opening
(left- or right-side venting only is recommended), using two
3.5 x 9.5 mm screws.
A
A. 3.5 x 9.5 mm screws
B. 6" (15.2 cm) round vent transition with damper
14
Complete Installation
/
" x 10"
1
4
1
/
" x 10"
4
A
A
B
2. Remove four screws attaching the terminal box cover.
A
A. Terminal box cover
3. Determine which direction (front or rear) the home power
supply cable will enter the terminal box. Remove the
appropriate knockout from the front or rear panel and install a
1/2" (1.3 cm) UL listed or CSA approved conduit connector.
4. Using two or more people, insert the downdraft vent into the
countertop cutout. Position downdraft vent so it is centered
in the cutout with the rear flange over the edge of the cutout
and the rear of the vent box against the edge of the cutout.
G
A. Rear flange of downdraft vent
B. Edge of cutout in countertop
C. Rear of downdraft vent
D. Cabinet back
A
B
C
D
E
F
E. Lower support leg
F. Cabinet floor
G. Countertop