Whirlpool UXI0600DYS Installation Instructions Manual - Page 8
Browse online or download pdf Installation Instructions Manual for Ventilation Hood Whirlpool UXI0600DYS. Whirlpool UXI0600DYS 20 pages. 600 cfm and 1200 cfm in-line blowers for range hoods
Also for Whirlpool UXI0600DYS: Product Dimensions (1 pages)
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical shock.
8. Connect the green (or green/yellow)
ground wire from the
wiring conduit to the green (or yellow/green)
ground wire (H)
in the terminal box using UL listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and
secure it with 10 mounting screws.
Electrical
Connection
Inside Range Hood Between
In-line
Blower System and Range Hood
1. With the range hood mounted (see the range hood installation
instructions),
locate the wiring cable connector inside the
range hood.
2. Connect the 6-wire connector assembly supplied with the
in-line blower motor system to the mating cable connector
from the range hood.
3=
Locate the terminal box inside the range hood and install a
1/2"(1.3 cm) UL listed or CSA approved strain relief (see the
range hood installation instructions).
4. Run the wire ends from the 6-wire connector assembly
through the 1/2"(1.3 cm) strain relief, leaving enough wire
length to make the wiring connections.
Tighten the strain
relief screws.
5. Connect the wires from the 6-wire connector assembly to the
wires from the wiring conduit inside the range hood terminal
box.
6. Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors (see the
"Make Electrical Power Supply Connections to Range Hood"
section in the range hood installation instructions).
B
C
A
D
A. UL listed or CSA approved
½" wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow)
wire
I. 6-wire connector assembly
7. Connect the home power supply wiring to the range hood
following the instructions
that are supplied with the range
hood.
8. Reinstall the range hood terminal box cover.
9. Reconnect power.
8