Whirlpool UXT5236AY Installation Instructions And Use & Care Manual - Page 13
Browse online or download pdf Installation Instructions And Use & Care Manual for Ventilation Hood Whirlpool UXT5236AY. Whirlpool UXT5236AY 32 pages. 30" (76.2 cm) and 36" (91.4 cm) range hood
Also for Whirlpool UXT5236AY: Installation Instructions And Use & Care Manual (36 pages), Installation Instructions And Use & Care Manual (34 pages), Installation Instructions And Use & Care Manual (32 pages)
To Replace the Filter:
1. To reinstall the filter, the single slot opening on the long edge
of the filter is to be toward the front of the range hood. Place
the back edge of the filter into the channel at the rear of the
range hood.
2. Pull the filter retainer toward the front of the range hood and
push the front of the filter up into place.
3. Release the filter retainer. It will spring back into place to
secure the filter.
4. Replace the screw into the filter retainer.
Replacing
the Halogen
Lamp
Turn off the range hood and allow the halogen lamp to cool. To
avoid damage or decreasing the life of the new lamp, do not
touch lamp with bare fingers. Replace lamp, using tissue or
wearing cotton gloves to handle lamp.
If new lamps do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect
power.
2. Push up on the lens and turn it counterclockwise.
3. Remove the lamp and replace it with a 120-volt, 50-watt
maximum halogen lamp with a GUIO base. Turn it clockwise
to lock it into place.
4. Repeat steps 2-3 for the other lamps if needed.
5. Reconnect power.
13