Whirlpool WVI30336LS Installation Instructions And Use & Care Manual - Page 4
Browse online or download pdf Installation Instructions And Use & Care Manual for Ventilation Hood Whirlpool WVI30336LS. Whirlpool WVI30336LS 32 pages. 30" and 36" (76.2 and 91.4 cm) island-mount canopy range hood
Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools Needed
■
Level
■
Drill with 1
/
" (3.2 cm),
1
4
and
/
" (2.75 mm) drill bits
7
64
■
Pilot hole drill bits (determined by chimney support
attachment method)
■
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Pliers
■
Caulking gun and weatherproof caulking compound
■
Vent clamps
■
Jigsaw or keyhole saw
■
Flat-blade screwdriver
■
Metal snips
■
Phillips screwdriver
■
T20
† Torx
adapter
®
®
Parts Needed
■
Home power supply cable
■
/
" (12.7 mm) UL listed or CSA approved strain relief
1
2
■
3 UL listed wire connectors
For Vented Installations, You Will Also Need:
■
1 wall or roof cap
■
Metal vent system
For Non-Vented (Recirculating) Installations,
You Will Also Need:
■
Recirculation Kit for non-vented (recirculating) installations
only. See the "Assistance or Service" section to order.
■
6" (15.2 cm) diameter round metal vent duct -
length required is determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
■
Hood ventilator assembly with canopy glass, retainer
brackets, rubber seals, and LED lights installed
■
Metal grease filter
■
60 - 4.2 x 8 mm screws
■
4 - 3.5 x 6.5 mm screws
■
4 - 5 x 45 mm screws
■
2 - 2.9 x 3 mm screws
■
2 - Leveling screws
■
4 - Washer
■
2 - Upper vent covers
■
2 - Lower vent covers
■
4 - Plastic vent clips
■
2 - 3.5 x 9.5 mm mounting screws
4
INSTALLATION REQUIREMENTS
/
" (9.5 mm),
/
" (3.2 mm)
3
1
8
8
■
Mounting template
■
2 - Horizontal support brackets
■
8 - Vertical supports
■
Vent transition with back draft damper installed
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall
of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical supply is required. See "Electrical
Requirements" section.
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
■
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 80 lbs (36.6 kg).
This range hood is recommended for use with cooktops with a
maximum total rating of
60,000
The range hood is factory set for venting through the roof or wall.
For non-vented (recirculating) Installation see "Non-vented
(recirculating) Installation" in "Install Range Hood" section.
Recirculation Kit is available from your dealer or an authorized
parts distributor. See the "Assistance or Service" section to
order.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280)
or, when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A,
or latest edition, or with local codes.
†
TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
®
BTUs or less.