Whirlpool WVI75UC6DS0 Installation Instructions And Use & Care Manual - Page 4
Browse online or download pdf Installation Instructions And Use & Care Manual for Ventilation Hood Whirlpool WVI75UC6DS0. Whirlpool WVI75UC6DS0 32 pages. 36"(91.4cm) island-mountcanopy range hood
INSTALLATION REQUIREMENTS
tbos Grid
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools needed
•
Level
•
Drill with 11¼"(3.0 cm), 3/8"(9.5 mm), %4" (2.75 mm) and
1/8"(3.0 mm) drill bits
•
Pilot hole drill bits (determined by chimney support
attachment
method)
•
Pencil
•
Wire stripper or utility knife
•
Tape measure or ruler
•
Pliers
•
Caulking gun and weatherproof
caulking compound
•
Vent clamps
•
Jigsaw or keyhole saw
•
Flat-blade screwdriver
•
Metal snips
•
Phillips screwdriver
Parts needed
•
Home power supply cable
•
1/2"(12.7 mm) UL listed or CSA approved strain relief
•
3 UL listed wire connectors
For vented installations,
you will also need:
•
1 wall or roof cap
•
Metal vent system
For non-vented
(recirculating)
installations,
you will also
need:
•
Recirculating
Kit Part Number W10294734 for non-vented
(recirculating)
installations only. See "Assistance
or Service"
section to order.
•
6" (15.2 cm) round metal vent duct. Length required is
determined by ceiling height.
Parts supplied
Remove parts from packages. Check that all parts are included.
•
Hood ventilator assembly with canopy glass, retainer
brackets, rubber seals, and LED lights installed.
•
Metal grease filter
•
60- 4.2 x 8 mm screws
•
4- 3.5 x 6.5 mm screws
•
2 - 2.9 x 3 mm screws
•
4-5x45mmscrews
•
T10 Torx ®t adapter
•
T20 ®tTorx ®adapter
•
2 - Upper vent covers
•
2 - Lower vent covers
•
4 - Plastic vent clips
•
Mounting template
•
Upper horizontal support bracket
•
Horizontal support
•
8- Vertical supports
•
Vent transition with back draft damper installed.
•
2 - 3.5 x 9.5 mm mounting screws
t®TORX and T20 are registered
trademarks
of Acument Intellectual Properties, Inc.
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the installer's
responsibility to comply with installation clearances specified on the
model/serial rating plate. The model/serial rating plate is located
behind the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions
provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements"
section.
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
•
For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 80 Ibs (36.6 kg).
This range hood is recommended
for use with cooktops with a
maximum total rating of 60,000 BTUs or less.
The range hood is factory set for venting through the roof or wall.
For non-vented (recirculating)
Installation see "Non-vented
(recirculating) Installation"
in "Install Range Hood" section.
Recirculating
Kit Part Number W10294734 is available from your
dealer or an authorized parts distributor.
All openings in ceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured
Home Construction
Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction
and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured
Home
Installation 1982 (Manufactured
Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
C
A. 12_" (31.1 cm)
B. 13_"
(33.5
cm)
C. "29_" (75.6 cm) min.
44 z_,, (113.8 cm) max.
*'29_" (75.6cm) min.
491_,, (126.5 cm) max.
E
D. 3½" (8.9 cm)
E. 36" (91.4 cm)
F..25_"
(64.0 cm)
*Vented installations only
**Non-vented
(recirculating)
installations only
D