Whirlpool WVW53UC6HV Installation Instructions And Use & Care Manual - Page 4

Browse online or download pdf Installation Instructions And Use & Care Manual for Ventilation Hood Whirlpool WVW53UC6HV. Whirlpool WVW53UC6HV 28 pages. 30" and 36" (76.2 and 91.4 cm) wall‑mount canopy range hood

Tools and Parts

Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools Needed
Level
Drill with 1
/
" (3 cm), 3/8" (9.5 mm), and 3/16" (4.8 mm)
1
4
drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Parts Needed
Home power supply cable
1/2" (12.7 mm) UL listed or CSA approved strain relief
Three UL listed wire connectors
For Vented Installations, You Will Also Need:
One wall or roof cap
Metal vent system
For Non-Vented (Recirculating) Installations,
You Will Also Need:
Recirculation Kit - See the "Assistance or Service" section to
order.
6" (15.2 cm) diameter round metal vent duct -
length required is determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with blower and LED lights installed
Vent transition with back draft dampers installed
Vent cover support bracket
Metal grease filter(s)
Mounting template
Two piece vent cover
Two 2.9 x 6.5 mm screws (Phillips)
Two 3.5 x 9.5 mm screws (Phillips)
Six 5 x 45 mm mounting screws (#2 Phillips)
Four 5.4 x 75 mm screws (Phillips) (for 10 x 60 mm
wall anchors)
Two 8 x 40 mm wall anchors (masonry)
Four 10 x 60 mm wall anchors
4

INSTALLATION REQUIREMENTS

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall
of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops with
a maximum total rating of 65,000 BTUs or less.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof
or wall. For non-vented (recirculating) installation, see "For
non-vented (recirculating) installation only" in the "Connect
Vent System" section. Recirculation Kit is available from your
dealer or an authorized parts distributor. See the "Assistance or
Service" section to order.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280)
or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A,
or latest edition, or with local codes.
Product Dimensions
30" (76.2 cm) or
36" (91.4 cm)
* For non-vented (recirculating) installations
** For vented installations
10"
(25.4 cm)
20" (50.8 cm)