Fig 3
Now WM5.0 device is ready for EA104 connection. Connection time is around 4 seconds for the device with
a unique Client ID. Otherwise, connection time varies from 10 to 40 seconds.
Note 1: When a WM5.0 device is plugged into the EA104, port the USB LED will flash. LED flashing means
the connection process is on-going. Important: During LED flashing, the user should not unplug a mobile
device from the USB port unless it takes more than 40 seconds. USB LED solid on after flashing means the
connection is established. LED off after flashing means the connection cannot be established, for example,
as caused by a duplicate ID conflict.
Note 2: If two or more EA104 units are installed in proximity to each other and there are
1. less than 49 WM5.0 devices to be used, it is recommended to keep the same USB IP Group value
for every EA104 (for example, keep default values 193.168.10.0).
2. more than 49 WM5.0 devices,
a. it is recommended to keep the same USB IP Group value for every EA104 and assign a
duplicate ID to those WM5.0 devices beyond 49. If an ID conflict arises from plugging in a
second device with the same IP, that device will be unable to make connection until its "twin"
is unplugged.
b. you can assign a different USB IP Group value to each EA104 (through "Network Settings –
USB Ports" page in AdminTool) and a set of WM5.0 devices. In this case, the connection
time is 4 seconds for the devices connecting to EA104 with the same USB IP Group value
and 10~40 seconds if connecting to EA104 with a different IP Group value.
You must use "Restore Default" to restore original settings in order to use the ActiveSync function between a
PC and a WM5.0 device, assuming original settings allow PC ActiveSync. You must also use "Apply Setting"
to enable any subsequent EA104 connection after "Restore Default".
Restore the WM5.0 device's original setting (the setting before changed by EtherUSB Client).
Go to Start->Programs folder and launch EtherUSB Client (Fig 1)
Select "Restore Default" (Fig 2)
http://www.clarinetsys.com/en/product-ea104.htm
Note: Please refer to
Clarinet Systems, Inc.
Fig4
//www.clarinetsys.com
for latest WM5.0 Devices Support.