DIR Orion H136WM Instruction Manual - Page 3

Browse online or download pdf Instruction Manual for Hair Dryer DIR Orion H136WM. DIR Orion H136WM 9 pages. Wall mounted

3 INSTALLATION OF MACHINE HEAD
CAUTION:DO NOT REMOVE STOPPER on Arm until machine
head is completely installed. Arm assembly is spring loaded
and could cause equipment damage and / or injury if not
handled in proper manner.
For both the arm assembly and the machine head are fairly
heavy, it is suggested that the installation is done by two
persons together as instructed in the following steps.
3-1 Remove the screw at the
protector plate underside and
rotate the protector plate
anti-clockwise till it is
vertical.Remove the hook lock
after loosening the screw.
Bracket
3-2 Stand the machine head on the
floor and keep it upright with two
hands.Another person holds up the
arm assembly and then inserts the tip
of the arm into the machine head
contact post.
Note one: Please make sure to insert the
machine head contact post firmly.The tip of
the arm assembly must be vertical adown.
You may also turn the tip of the arm assembly
left or right slightly and press the tip of the arm
assembly slightly.
Note two: The tip of the arm assembly must be
in osculated completely with the head contact
post.Please pay more attention to the groove
of the bracket, if you can see the groove of the
machine head contact post through the groove
of the bracket, it shows the installation position
is correct.
3-3 Reinstall back the hook lock to
the groove and then tighten the
screw firmly.
Stopper
Protector Plate
Hook Lock
Groove
Tip of Machine Head
Contact Post
Hook Lock
3-4 Turn the protector plate clockwise back to the original
position and then tighten the screw firmly.
3-5 Two persons hold up the machine head and the arm assembly at
the same time, then install on the wall.
3-6 Remove the stopper, otherwise it will damage the arm assembly!
Stopper
Protector Plate