Direct Flow S800 User Manual - Page 7

Browse online or download pdf User Manual for Water Dispenser Direct Flow S800. Direct Flow S800 8 pages. Direct flow reverse osmosis water systems

Change membrane

1
Unplug electricity.
3
Loose the Jaco fitting anticlockwise.
Jaco
5
Remove the membrane by a pincer.
S800-Direct Flow Reverse Osmosis Water Systems
2
Turn off water source.
To RO system
4
Remove the membrane housing
cap anticlockwise.
6
Install the membrane by carefully
pushing the spigot end into the
socket at the far end of the housing
until completely in.

Tubing connection diagram

CONNECTING THE COLOR TUBING:
A. Connect the WHITE tubing to the water supply connector.
B. Connect the BLUE tubing to the sink top faucet.
C. Connect the BLACK tubing to the drain saddle.
Faucet
B
S300RD
S800-Direct Flow Reverse Osmosis Water Systems
8
C
A
Drain
c
PUREPRO USA CORP., ILLINOIS, U.S.A.
S300ND
S 300ST
DRAIN
OUTLET
INLET
Input water