3. Commissioning
On commissioning you have to adjust primarily the matching system
Operation cont-
rol lamp
backwards
2
(Selection / Adjustment mode)
Arr 1
4.
Controller parameter and indication channels
4.1 Channel-overview
Legend:
x
Corresponding channel is available.
x*
Corresponding channel is available if the appropriate option
is activated.
Corresponding channel is only available if the option heat
quantity measurement is activated (OWMZ).
Please note:
S3 and S4 are only indicated if sensors are connected.
Arr
channel
1
2*
COL
x
x
Temperature collector 1
TST
x
Temperature tank 1
TSTL
x
Temperature tank 1 below
TSTU
x
Temperature tank 1 above
S3
x
Temperature sensor 3
TRF
Temperature return sensor
S4
Temperature sensor 4
h P1
x
Operating hours relay 1
h P2
x
Operating hours relay 2
kWh
Heat quantity kWh
MWh
Heat quantity MWh
Arr
1-2
System
DT O
x
x
Switch-on temperature difference
DT F
x
x
Switch-off temperature difference
S MX
x
x
Maximum temperature tank 1
EM
x
x
emergency temperature collector 1
8
|
forward
1
3
SET
Arr 2
specification
page
9
9
9
9
9
9
9
9
9
10
10
8
10
10
10
10
1. Ac power supply must be activated. The controller passes
an initialisation phase in which the operating control lamp
flashes red and green. After having finished the initialisation,
the controller is in automatic operation with factory set-
tings. The preadjusted system scheme is Arr 1.
2. - select Arr
- change into
-mode (see 2.1)
- select the system scheme by Arr-characteristics
- adjustment is saved by pressing button
Now the controller is ready for operation and should enable
an optimum operation of the solar system by the factory
settings made.
System survey:
Arr 1 : standard solar system
Arr 2 : solar system with after-heating
Corresponding channel is only available if the option heat
quantity measurement is deactivated (OWMZ).
MEDT
The channel antifreeze content (MED%) is only shown if a
medium other than water or Tyfocor LS / G-LS (MEDT
0 or 3) is used. The adjustment is only appropriate when
using other types of antifreeze.
Arr
channel
1
2*
OCX
x
x
Option collector cooling collector 1
CMX
x*
x*
Maximum temperature collector 1
OCN
x
x
Option minimum limitation collector1
CMN
x*
x*
Minimun temperature collector 1
OCF
x
x
Option antifreeze collector 1
CFR
x*
x*
Antifreeze temperature collector 1
OREC
x
x
Option reccoling
O TC
x
x
Option tube collector
AH O
x
Switch-on temp. for thermostat 1
AH F
x
Switch-off temp. for thermostat 1
OHQM
x
x
Option WMZ
FMAX
Maximum flow
MEDT
Antifreeze type
MED%
MEDT MEDT Antifreeze content
HND1
x
x
Manual operation relay 1
HND2
x
x
Manual operation relay 2
LANG
x
x
Language
UNIT
x
x
Change over °FAH / °CEL
PROG
XX.XX
Program number
VERS
X.XX
Version number
specification
page
11
11
11
11
11
11
11
12
12
12
12
12
10
10
12
12
12
12