Caleido M1/M1CR Technical Manual - Page 6

Browse online or download pdf Technical Manual for Food Warmer Caleido M1/M1CR. Caleido M1/M1CR 9 pages. Digital control for towel warmer

• The electronic thermostat may only be connected to the heating element by qualified personnel.
• Ensure that the power of the resistance does not exceed the maximum power allowed by the electronic control.
CONNECTION TO THE FIL-PILOT SYSTEM
(For versions with Fil-Pilot only) Example:
1. M1 / M2 with "Fil-Pilot" function (class II) can be remotely controlled by a control unit that supports the "Fil-Pilot" system. The brown wire is
live (L), the grey wire is neutral (N), and the black wire is used to receive the Fil-Pilot signal.
Do not connect the black wire to earth.
2. M1 / M2 without "Fil-Pilot" function (class I) cannot be remotely controlled.
The brown wire is live (L), the blue wire is neutral (N), and the yellow/green wire must be connected to earth.
FIL-PILOT
The "Fil-Pilot" system manages six different types of signal.
1. Standby: switches off the heating element, but the thermostat stays on.
2. Comfort: maintains the "Comfort" temperature set by the user.
3. ECO: maintains the temperature 3.5°C below the "Comfort" temperature.
4. Anti-freeze: prevents the temperature from falling below 7°C.
5. Eco-1: maintains the temperature 1°C below the "Comfort" temperature.
6. Eco-2: maintains the temperature 2°C below the "Comfort" temperature.
USER MANUAL
Operating mode icons:
1) Fil-Pilot
2) Comfort
3) Night
4) Antifreeze
5) Timer
6) Chrono
(in the following order from left to right).
Function:
"Open window sensor".

"ON / STAND-BY" BUTTON

Press the [On/Stand-by) button to switch on the appliance or activate the "Stand-by" mode.
When active, the lower area of the display shows the current time, while the mode setting, and temperature are shown at the top. During
"Stand-by" the display shows "Stb", the current time and the day of the week.
NOTE: When the device enters 'Stand-by' mode, two 0.5 second beeps are emitted. When the device is switched on, one
1-second beep is emitted.
6
• Always disconnect the electricity supply from the mains during installation.
Living room
Bathroom
Class II
thermost
at
~230V
AC/50HZ
Switch
Thermostat
Heating element
active symbol.
Comfort Bar/Night
mode Chrono.
Day of the week.
Example of the display in "Comfort" mode.
Room 1
Class II
Class II
thermost
thermost
at
at
"Fil-Pilot"
Live
Neutra
l
Switch
Switch
"Fil-Pilot"
station
Thermostat
Thermostat
Set temperature
24h indicator.
Remote control signal
reception indicator
Clock.
"Key lock" icon
Fil-Pilot
Example of the display in "Stand-by" mode.
Room 2
Class I
thermost
at
Switch
Thermostat
Anti-
Comfort
Night
2H timer
freeze
Chrono