calentador Supreme 14e Installation & Maintenance - Page 5
Browse online or download pdf Installation & Maintenance for Water Heater calentador Supreme 14e. calentador Supreme 14e 9 pages. Domestic gas water heater
SUPREME E
•
Remove the adjustment knobs.
•
Undo the two screws and remove the cover.
•
Disconnect the connector of the microswitch and controller
•
Undo the screw and remove the controller assembly
•
Undo the four modulation cone cover fixing screws.
•
Remove the spring and replace the modulation cone (ref. 1 - fig. 12) with
one suitable for the new type of gas, making sure the gasket (ref. 2 - fig. 12)
is correctly positioned.
5
fig. 10
fig. 11
fig. 12
cod. A73020280 - Rev. 01 - 02/2013
•
Undo the four burner fixing screws and pull out the tray.
• Replace the nozzles at the main burner and pilot burner, fitting the nozzles
indicated in the technical data table in cap. 5, depending on the type of gas used
• Apply the sticker, contained in the conversion kit, near the data plate as proof of
the conversion.
4.2 Commissioning
Before lighting the water heater
• Check the tightness of the gas system.
• Fill the hydraulic system and make sure the air in the water heater and system is
completely vented.
• Make sure there are no water leaks in the system and unit.
• Check the correct gas pressure value.
• Make sure there are no flammable liquids or materials in the immediate vicinity of
the water heater.
Checks during operation
• Turn the unit on.
• Check the tightness of the fuel circuit and water systems.
• Check the efficiency of the flue and fume ducts when the water heater is operating.
• Check correct lighting of the water heater by turning it on and off several times.
• Make sure the fuel consumption indicated on the meter matches that given in the
technical data table on cap. 5..
fig. 13
fig. 14