Calex PMB21 Operator's Manual - Page 7

Browse online or download pdf Operator's Manual for Accessories Calex PMB21. Calex PMB21 17 pages.

Calex PMB21 Operator's Manual

LIST OF MODBUS REGISTERS

The list below includes all available addresses on the PyroMiniBus sensor.
R = Read, W = Write
Address
Length (words)
0x00
1
0x01
1
0x02
2
0x04
1
0x05
1
0x06
1
0x07
1
0x08
1
0x09
1
0x0A
1
0x0B
1
0x0C
1
0x0D
1
0x0E
1
0x0F
1
0x10
1
0x11
1
0x16
1
0x17
1
Notes:
1
All temperature are in tenths of degrees C
2
With the exception of addresses 0x16 and 0x17, all write operations are saved to non-
volatile memory
3
For further information please refer to http://www.modbus.org/specs.php
4
Use address 255 to communicate with any connected sensor (only one sensor
connected)
5
Use address 0 to broadcast to all connected sensors (no response expected)
Description
Sensor Type (17 for PyroMiniBus)
Field of view 0 for 2:1; 1 for 20:1
Serial number
Modbus slave ID (slave address)
Reflected Energy Compensation 0 for Off; 1 for On
Reflected Temperature
Emissivity Setting (1 LSB = 0.0001)
Minimum 0.2000, Maximum 1.0000
Hold Mode 0 for Off; 1 for Peak; 2 for Valley
Hold Period (1 LSB = 0.1 seconds)
Minimum 0.1 seconds, Maximum 1200.0 seconds
Average Period (1 LSB = 0.1 seconds)
Minimum 0.1 seconds, Maximum 60.0 seconds
Average Temperature
Minimum Temperature
Maximum Temperature
Filtered Temperature
Unfiltered Temperature
Sensor Temperature
Status (bits active high)
Bit 0: Measurement error
Bit 1: Sensor temperature low
Bit 2: Sensor temperature high
Bit 3: Object temperature low
Bit 4: Object temperature high
Reflected Temperature (not saved to non-volatile
memory)
Emissivity Setting (not saved to non-volatile
memory)
R/W
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
R/W
R/W
7