PyroMiniBus non-contact infrared sensors measure temperatures from -20°C to 1000°C and
provide an RS485 Modbus RTU interface.
The sensors are capable of being used in ambient temperatures up to 120°C without cooling
(XCF models: 70°C). They may be connected directly to third-party Modbus Masters, and they
are compatible with the optional PM180 6-channel touch screen interface, which provides
temperature display, data logging, alarms and analogue outputs.
A 6-channel junction box (model PMBHUB) is available to easily connect PyroMiniBus sensors
to the PM180 as a complete temperature measurement system.

SENSOR SPECIFICATIONS

Model Numbers
Field of View
2:1
20:1
Close Focus (Ø3.5 mm at distance 50 mm)
General
Interface
Accuracy
Repeatability
Emissivity
Response Time
Spectral Range
Supply Voltage
Supply Current
Baud Rate
Format
Mechanical
Construction
Dimensions
Thread Mounting
Cable Length
Weight with 1 m Cable
Environmental
Environmental Rating
Ambient Temperature
Relative Humidity
* Other configurations available upon request
2
RS485 Modbus RTU
±1% of reading or ±1°C whichever is greater
± 0.5% of reading or ± 0.5°C whichever is greater
0.2 to 1.0
125 ms (90% response)
8 to 14 μm
24 V DC (minimum sensor voltage 6 V DC, maximum 28 V DC)
50 mA max.
9600 baud *
8 data bits, no parity, 1 stop bit *
Stainless Steel
18 mm diameter x 45 mm long (excluding cable gland)
M16 x 1 mm pitch
1 m standard, longer cable available to order
85 g
IP65
0°C to 120°C (XCF models: 70°C)
95% max. non-condensing
Model Number
PMB21
PMB201
PMBXCF