Xerox Document Binder 120-D (DB120-D)

Electrical Requirements

Device
Document Binder120-D
DocuPrint DocuTech 75/90
Bypass Transport

Environmental Requirements

Estimated Installation Time

The recommended location of the electrical wall outlet, mounted
on a rear wall is to be no more than 6 feet (1,829mm) away from
the rear center of the Document Binder 120-D.
North America
115 VAC, 60 Hz, 7A
Power cord: 6 - 8 ft (1,829 –
2,438 mm)
105 - 127 VAC 60 Hz, 2 A
Device
Document Binder120-D
Temperature
50 - 90° F (10 - 32°C)
Humidity
10 – 85% (non-condensing)
Heat Emission
108 btu / hr. (Energy Saver mode)
809 btu / hr. (Standby mode)
1106 btu / hr. (Operating mode)
Sound Emission
Standby: 46 dB
4 sheets binding: 68 dB
30 sheets binding: 66 dB
100 sheets binding: 66 dB
Altitude
0 – 13,000 ft. (0 – 4,000 m)
In North America, the CoverBind personnel install the DB120-D
and the estimated installation time is 2 hours. CoverBind
personnel also provides an initial 2 – 4 hour customer training.
In Europe, Bindomatic personnel install the DB120-D and the
estimated installation time is 2 hours. Bindomatic personnel also
provides an initial 2 – 4 hour customer training..
To contact Bindomatic and / or Coverbind, please go to:
Contact Information
1-5
Europe
220VAC, 50 Hz, 3.5A
Power cord: 6 - 8 ft (1,829 –
2,438 mm)
N/A