Also for Xerox Nuvera 100: Specification Sheet (2 pages), Features Manual (34 pages), Planning Manual (22 pages), User Manual (40 pages), Operation Manual (34 pages), Reference Manual (2 pages), Planning Manual (20 pages), Reference Manual (42 pages), Quick Reference (2 pages), Install Manual (2 pages), Supplementary Manual (48 pages), Planning Manual (38 pages), Planning Manual (16 pages), Reference Manual (2 pages), Specifications (2 pages), Hints And Tips Manual (18 pages), Getting Started Manual (26 pages), Getting Started Manual (30 pages)

Xerox Nuvera 100 Hints And Tips Manual
Release Issues
Xerox Nuvera

CQ#38117 Short Edge Feed 9x11 Stock

Description
9 x 11 stock cannot be loaded short edge first (SEF).
Workaround
Load an SEF-only stock such as Legal, run one or more sheets on that stock, then unload it and
put in 9x11 S
CQ#26871 Queue and Job based subsetting fails for Odd
number of pages duplex jobs
Description
Subset offset and finishing can be programmed on job in the job manager or on a Queue. This
works fine for simplex jobs. It will also work for duplex jobs as long as the request is for an
even number of images. But if the request is for a subset that would require a duplex page to
be split then the request fails.
Workaround
.
Only program even number of pages in the subset
CQ#47602 DS3500 finisher: a Job integrity issue may occur if
the unload button is pressed just before the first sheet is
delivered
Description
IF the user presses the DS3500 stacker unload button just before the first sheet of the job
reaches the stacker, there may be a jam in the flipping wheel area which could cause job
integrity issues.
Workaround
Please do not press the DS3500 stacker unload button just before receiving the first sheet of a
job

CQ#47579 Non-clearable Top Edge Sensor Fault

Description
If a Top Edge Sensor fault occurs and the machine is restarted with the IOT doors open, a non-
clearable Top Edge Sensor Fault may occur.
Workaround
Close the IOT doors and then Power-off/Power-on the machine and the fault will clear. To
avoid the occurrence, ensure the IOT doors are closed before restarting the machine.
3-4