CALF-STAR Milk Jug Manual - Page 10
Browse online or download pdf Manual for Commercial Food Equipment CALF-STAR Milk Jug. CALF-STAR Milk Jug 14 pages.
Also for CALF-STAR Milk Jug: Manual (12 pages)
5. o
peratIon
^
Safely operate equipment.
Allow only properly trained and qualified
personnel to operate this equipment.
^
Do not operate without guards and
shields in place.
^
Do not operate, work on or around this machine
while under the influence of alcohol, drugs or if
feeling ill.
^
It is your responsibility to operate this equipment
safely. You must be familiar with the equipment
and all safety practices before use.
^
Do not allow untrained or unqualified people to
operate this equipment.
5.1 p
-o
re
peratIon
Review and understand this manual.
Verify all guards are installed and covers are closed
and latched. Verify all personnel are clear of machine.
5.2 C
oolIng
The Milk Jug is designed to cool milk from 60°F - 70°F
down to 40°F. Adding milk that is warmer than 60-
70°F will result in a slower cooling process
Close shutoff/butterfly valve on bottom of tank. Fill
Milk Jug with tempered milk. Touch Off/On button. Go
to Cooling Menu.
10
WARNING
WARNING
C
l
HeCk
Ist
Once milk level rises above safety float, the cooling
will start.
The agitator will also start at this time. Once milk
cools to desired set-point, cooling will turn off until the
temperature rises above re-cool threshold.
During the rest time, agitator will still cycle to assure
that milk components stay in suspension.
When milk level falls below safety float, cooling
system will disengage so milk does not freeze to the
bottom of tank.
5.3 s
d
ettIng
etergent
The Milk Jug comes with a Clean In Place (CIP)
system that utilizes a single step wash system. It is
important that you use a One-Step Acid Detergent
product such as BouMatic Brilliance™. To program
the detergent pump:
Go to Setup.
1.
Touch Wash Setup.
2.
Touch Detergent Per Wash Cycle. A keypad will
3.
popup. Type in number and touch return button to
enter value.
p
ump
Calf-Star Milk Jug