3. MAIN FEATURES
• Brushless motor 200-480Vac, 3ph, 50/60Hz, IP 65
• Speed controllable
• Suitable for S1 continuous service
• Embedded system
• Anodized extruded blades
4. DATA @400Vac, 50/60Hz
No
Max speed
Model
absorbed
blades
rotation
rpm
QHS300
5
135
QHS400
5
100
QHS500
5
68
QHS600
5
55
QHS660
5
46
(1) max. absorbed power / max. airflow
(2) min. average air speed 0.8 m/s with testing layout in conformity with AMCA 230
(3) Sound testing taken with the sensor 1,5m above the floor and 6m from the centre of the fan at 5m high, measured in a laboratory environment. Actual results in field conditions may vary due to sound reflecting
surfaces and environmental conditions.
5. DIMENSIONS AND CLEARANCES
Model
QHS300
QHS400
QHS500
QHS600
QHS660
6. COMPONENTS
• The fan is delivered split into two kits, each one in its own crate.
• MOTOR KIT includes:
- main body (Fig.I - 1).
- standard 800mm length downrod (Fig.I - 2).
- 2x ceiling fixing brackets (Fig.I and VI - 3).
- 2 fixings sets:
- 4x M12 bolts (Fig.I - 4), 4x locknuts (Fig.I - 5), 4x standard washers (Fig.I - 6) and 4x spring washers (Fig.I - 7), for fan fixing
to the ceiling.
- 10x M8 flange bolts (Fig.VIII - 8), 10x locknuts (Fig.VIII - 9) and 10x spring washers (Fig.VIII - 10), for blades fixing to main body.
- plastic components set: hub cover (Fig.IX - 11), 5x M4 bolts (Fig.IX - 12), 5x plastic blade terminals (Fig.VIII - 13) and 10x
screws (Fig.VIII - 14).
- electric cables with plugs (Fig.III - 15).
- security wires set: 1x Ø5mm security wire with one ring (Fig.I and II - 16), 2x Ø5mm wire with two rings (Fig.II - 17), 2x clamp
(Fig.VII - 18), 2x 7mm snap-hook (Fig.II and V - 19), 1x shackle (Fig.II - 20), for the security wire. 4x Ø3mm stabilizing wires
with turnbuckle (Fig.X - 21), 5x 5mm snap-hooks (Fig.X and XI - 22) and 8x clamp (Fig.XIII - 23), for the stabilizing wires.
• BLADES KIT incudes five blades (Fig.VIII - 24).
Max
Max
Max
current
Thrust
power
kW
A
N
cfm
0,97
2,6
114
78946
1,04
2,5
147
119039
0,90
2,3
121
134667
0,90
2,2
170
191230
0,80
2,2
175
213264
B
ØA
min safety distance
max ceiling slop
from side obstacle
mm
mm
>
°
3050
350
4050
450
5050
15
550
6050
550
6650
650
• Gearless for silent operation
• Maintenance-free
• Key Safety features
• Simplified electrical wiring connection
• Strong and robust design and manufacturing
Max airflow
AMCA 230-99
SPI
(1)
m
3
/h
cfm
(W/m
3
/s)
134130
26,0
55823
202248
18,5
84173
228800
14,2
95224
324901
10,0
135220 229740
362337
7,9
150801 256211
ØA
D
C
fan height
with standard
downrod length
downrod
mm
1250
1270
1270
1304
1304
11
Max airflow
Affected
AMCA 230-15
diameter
SPI
(1)
m
3
/h
m
(W/m
3
/s)
94844
36,8
14
143011
26,2
21
161786
20,0
24
14,1
31
11,2
38
C
E
H
standard
min fan
installation height
mm
mm
800
2700
Sound
Sound
pressure
pressure
2)
100%
50%
(3)
(3)
dB(A)
dB(A)
56
41
54
39
50
35
50
35
49
34
Weight
kg
80
91
101
118
123