Alderon Industries Versa'larm 8125 Operation, Maintenance And Installation Manual
Browse online or download pdf Operation, Maintenance And Installation Manual for Security System Alderon Industries Versa'larm 8125. Alderon Industries Versa'larm 8125 4 pages.
Versa'larm
Part Numbers - 8124 (alarm panel only) and 8125
Manual Alarm Reset
Operation, Maintenance and Installation Manual
Introduction of Installation
Safety Guidelines
1. DISCONNECT ALL ELECTRICAL SERVICE BEFORE INSTALLING OR WORKING ON THE PRODUCT.
2. DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC.
DO NOT USE IN EXPLOSIVE ATMOSPHERES.
3. ALARM PANEL MUST BE MOUNTED INDOORS. FOR OUTDOOR APPLICATIONS CONSULT FACTORY.
Description of Operation
The 1-Zone Manual Alarm Reset Versa'larm™ alarm panel is powered by 120 VAC coming from standard wall outlets and
is transformed to 9-11.1 VDC. Installing a 9 Volt battery provides battery backup during power outages. The power LED
(green) will illuminate when powered. The Manual Alarm Reset Versa'larm™ is a multipurpose alarm panel that can be
used in a variety of applications such as: septic tanks, sumps, holding tanks, pump chambers, water tanks, flow, pressure,
condensate, temperature and any others where a "dry contact" can be connected to the alarm panel.
When a switch (signaling device) contact "closes" the buzzer will annunciate, alarm LEDs (red) will illuminate (Alarm Sensor
and Alarm Reset), and the built in auxiliary contacts will be activated. The signaling device could be a float switch, water
sensor, or sump probe sensor.
Pressing the "Silence/Reset" pushbutton will silence the buzzer and the alarm LEDs (red) remain on. When the switch is
deactivated, the buzzer, "Alarm Sensor" LED, and normally open dry contacts will automatically reset. The "Alarm Reset"
LED and normally closed dry contacts remain activated until the "Silence/Reset" pushbutton is pressed a second time,
which will reset the alarm panel for the next alarm cycle.
Tools, Supplies and Requirements for Installation - Not Included
1. Phillips screw driver
2. (Qty 2) #6 self-tapping screws
3. Access to 120 VAC power receptacle
4. Needle nose pliers (battery cover for auxiliary contacts)
5. Optional - Plastic anchors (#8; Qty 2) if mounting to sheet rock
6. Optional - 9V battery (used for battery backup during power outages)
7. Optional - Wire stripper (used if you need to strip wire to connect to the auxiliary contacts)
IOM000027_Rev02_Versa'larm 1-Zone Manual Alarm Reset | April 7, 2018 11:47 AM
Alarm Systems
Control Panels
Alderon Industries - Hawley, MN | 218.483.3034 | [email protected] | alderonind.com
™
Before proceeding with the installation or operation of the product, read all
instructions thoroughly, as well as complying with all federal, state and local
codes, regulations, and practices. The product must be installed by qualified
personnel familiar with all applicable local electrical and mechanical codes.
Refer to the National Electrical Code (NFPA 70). Failure to properly install and
test this product can result in personal injury or equipment malfunction.
Float Switches
Leak Detection Systems
P/N: IOM0000027
1 of 4