eControls Comfort 365 C365T11 Installer Manual - Page 8

Browse online or download pdf Installer Manual for Thermostat eControls Comfort 365 C365T11. eControls Comfort 365 C365T11 8 pages.

ACCESSING THE TEST MENU

The Test Menu is used to test the Indoor Fan Operation, Allowable
Heating Airflow Limits and Allowable Cooling Airflow Limits.
To access the Test Menu,
TOUCH
seconds until the fan test screen (Option 01) appears.
Upstairs
Airflow %
Auto
Downstairs
Day
Tu
AM
MENU
MODE
TOUCH
and
to access the Installer Options.
01-02 Testing Indoor Fan Operation
This test is used to verify that the indoor fan is operating correctly.
In Option 1, the Fan is Off.
Touch
NEXT
to go to Option 2
to turn on the indoor fan. Verify
the fan is operating and
delivering airflow to the
upstairs and downstairs..
Touch
NEXT
to go Testing
Heating Airflow Limits.
03-04 Testing Heating Airflow Limits
This test is used to determine the maximum allowable upstairs airflow
and the maximum allowable downstairs airflow in HEATING.
In Option 3, the system is Off.
Touch
NEXT
to go to Option 4
to activate heating. Verify the
equipment is operating.
To determine the maximum
allowable upstairs airflow,
touch the
UP
key until the
airflow is too great and causes
noise or annoyance. Lower the
airflow using the
DOWN
key
until it is acceptable. This is the
maximum allowable upstairs
airflow in heating. Record the
airflow value.
Maximum Allowable Upstairs Airflow in Heating
and
HOLD
the hidden Next key for 7
Cool
Set To
Schedule
Inside
COOL
SYSTEM
AUTO
FAN
HOLD
this key for 7 seconds
Upstairs
Test
Airflow %
Downstairs
NEXT
ENTER
Upstairs
Test
Airflow %
Downstairs
NEXT
ENTER
Upstairs
Heat
Test
Airflow %
Downstairs
NEXT
ENTER
Upstairs
Heat
Test
Airflow %
Downstairs
NEXT
ENTER
03-04 Testing Heating Airflow Limits (cont.)
To determine the maximum
allowable downstairs airflow,
touch the
DOWN
key until the
airflow is too great and causes
noise or annoyance. Increase
the airflow using the
UP
until it is acceptable. This is the
maximum allowable downstairs
airflow in heating. Record the
airflow value.
Maximum Allowable Downstairs Airflow in Heating
Touch
NEXT
to go to Testing Cooling Airflow Limits.
05-06 Testing Cooling Airflow Limits
This test is used to determine the maximum allowable upstairs airflow
and maximum allowable downstairs airflow in COOLING.
In Option 5, the system is Off.
Touch
NEXT
to go to Option 6
to activate cooling. Verify the
equipment is operating.
To determine the maximum
allowable upstairs airflow,
touch the
UP
key until the
airflow is too great and causes
noise or annoyance. Lower the
FAN
airflow using the
DOWN
until it is acceptable. This is the
maximum allowable upstairs
airflow in cooling. Record the
airflow value.
Maximum Allowable Upstairs Airflow in Cooling
FAN
To determine the maximum
allowable downstairs airflow,
touch the
DOWN
key until the
airflow is too great and causes
noise or annoyance. Increase
the airflow using the
UP
until it is acceptable. This is the
maximum allowable downstairs
airflow in cooling. Record the
airflow value.
Maximum Allowable Downstairs Airflow in cooling
Touch
ENTER
to end testing and return to normal thermostat
operation.
Enter the maximum airflow limits using Options 17
through 20 of the installer menu.
8
Upstairs
Test
Airflow %
Downstairs
key
NEXT
Upstairs
Test
Airflow %
Downstairs
NEXT
Upstairs
key
Test
Airflow %
Downstairs
NEXT
Upstairs
Test
Airflow %
Downstairs
key
NEXT
Heat
ENTER
Cool
ENTER
Cool
ENTER
Cool
ENTER