Set System Mode
Touch the SYSTEM key to display the SYSTEM MODES - OFF, HEAT,
COOL, or AUTO. When HEAT is selected, the heating setpoint is
displayed. When COOL is selected, the cooling setpoint is displayed. In
AUTO or OFF, the setpoint for the last system call is displayed.
Upstairs
Heat
Airflow %
Set To
Auto
Schedule
Downstairs
Inside
Day
Tu
SYSTEM
AM
MENU
MODE
Set Fan Mode
Touch the
FAN
key to display the FAN MODES - AUTO or ON. AUTO is
the most commonly used setting.
Upstairs
Airflow %
Cool
Set To
Auto
Schedule
Downstairs
Inside
Day
Tu
SYSTEM
AM
MENU
MODE
Set Thermostat Mode
Touch the
MODE
key to display the THERMOSTAT MODES -
SCHEDULE, HOLD and VACANT.
In SCHEDULE MODE, the setpoint temperature is automatically
changed at the scheduled times as long as the SYSTEM MODE is in
AUTO. In HOLD MODE, the thermostat uses the temperatures set by
the user, ignoring the schedule. In VACANT MODE, the thermostat
uses the energy saving Vacant heating and cooling setpoints set by the
installer until the mode is changed.
Upstairs
Airflow %
Cool
Set To
Auto
Schedule
Downstairs
Inside
Day
Tu
SYSTEM
AM
MENU
MODE
Displays the Mode.
Touch and hold the SYSTEM key
to select:
OFF
Heating and cooling systems
are off.
HEAT
HEAT
Only heating calls are enabled.
COOL
Only cooling calls are enabled.
AUTO
FAN
AUTO
Heating or Cooling calls are
enabled.
Touch FAN key to select:
AUTO
Fan is activated only during
heating or cooling calls.
COOL
ON
Fan is continuously on.
AUTO
FAN
Touch and hold the MODE key
to select:
SCHEDULE
Setpoint temperatures are changed
COOL
at scheduled times defined by the user.
HOLD
AUTO
Setpoint temperatures are set by
FAN
the user. No schedule is used.
VACANT
Setpoint temperatures are kept at the
vacant temperatures set by the installer.
Changing the Setpoint Temperature
The UP/DOWN keys are used to change the setpoint temperature.
Upstairs
Airflow %
Cool
Set To
Auto
Schedule
Downstairs
Inside
Day
Tu
AM
MENU
MODE
To display the opposing system setpoint, touch the area shown below.
Upstairs
Heat
Airflow %
Set To
Auto
Schedule
Downstairs
Inside
Day
Tu
AM
MENU
MODE
Temperature Override
If the thermostat is in SCHEDULE MODE, the setpoint temperature can
be overridden using the UP/DOWN keys. The setpoint temperature will
be held for 3 hours. After 3 hours the thermostat returns to normal
operation.
Upstairs
Airflow %
Cool
Set To
Auto
Schedule
Downstairs
Inside
Day
Tu
AM
MENU
MODE
Displaying the Upstairs Temperature
The thermostat displays the downstairs temperature and is indicated
by INSIDE. The upstairs temperature will be indicated by INSIDE2. In
Night Mode, the thermostat displays the upstairs temperature,
indicated by INSIDE2.
Upstairs
Airflow %
Cool
Set To
Auto
Schedule
Downstairs
Day
Inside2
We
AM
MENU
MODE
5
Touch the UP key to raise setpoint
temperature.
Touch the DOWN key to lower setpoint
COOL
temperature.
SYSTEM
An active heating call is indicated by
AUTO
HEAT blinking. An active cooling call
FAN
is indicated by COOL blinking.
Touch here to display and change
the opposing setpoint temperature.
Touch the UP/DOWN keys to change the
COOL
setpoint temperature for the opposing
SYSTEM
system. The thermostat will return to
AUTO
displaying the active setpoint after about
FAN
30 seconds.
Touch the UP/DOWN keys to adjust the
setpoint temperature.
After 3 hours, the thermostat returns
COOL
to normal thermostat operation.
SYSTEM
AUTO
FAN
To display the upstairs temperature,
touch the INSIDE temperature as
indicated. The thermostat will now
display the upstairs temperature,
COOL
indicated by INSIDE2.
SYSTEM
AUTO
After about 30 seconds, the
thermostat will return to displaying
FAN
the downstairs temperature.