eControls ECOM E2046013 Installation Manual - Page 12
Browse online or download pdf Installation Manual for Cables and connectors eControls ECOM E2046013. eControls ECOM E2046013 12 pages. Ecom driver installation
- 1. Table of Contents
- 1. 1 Introduction
- 2. 2 Ecom Tm Installation Procedure
- 2. Running the Setup Program
- 2. Connecting the ECOM
- 2. Verifying ECOM™ Installation
- 3. 3 Troubleshooting Ecom Tm Issues
- 3. General Troubleshooting
- 3. Windows 10 Driver Installation Issues
- 3. Windows 7 Driver Installation Issues
00: CUSTOMER
(see detail on Title Page)
Flashing Red CAN/SERIAL LED, No Communication:
installation problem, physical CAN hardware issues and other wiring problems will prevent you
from communicating with other CAN nodes. These types of errors can be easily identified by
looking for a red flashing LED on the ECOM
error, which can often be fixed by resolving one of the following common problems:
Wiring is disconnected or CAN-H and CAN-L wires are reversed
The software using the ECOM
proper baud rate for your bus and controllers and then reconfigure your software to match.
The CAN bus requires at least one 120 ohm terminating resistor connected between CAN-H
and CAN-L in order to function properly. If the CAN bus you are connecting to is already
functional, this would imply it already has the terminating resistor and thus should not be a
problem. Consult your CAN documentation for specifics about the terminating resistors.
The red flashing light on the CAN LED will also occur if there is no other node on the CAN bus
when the ECOM
activate another CAN device in order to resolve this error.
3.2
Windows 10 Driver Installation Issues
Unable to connect to ECOM™ on a Windows 10 PC: As a security measure, the Microsoft Windows
10 OS includes a feature that, when enabled, requires digital signatures on installed drivers. In
order for installation of the ECOM™ driver to be successful on Windows 10 PCs, driver software
version 3.5.0.0 or later must be used.
3.3
Windows 7 Driver Installation Issues
Windows can't verify the publisher of this driver software: Ensure that Windows 7 has the
security update KB3033929 (This was a critical security update released March 2015) installed. If
this update isn't installed, the driver installer will report that the driver signature is invalid or
corrupted.
EControls LLC. Confidential and / or proprietary information. Do not copy or distribute without prior written approval.
TM
ECOM
Installation Manual
TM
device is configured for the incorrect baud rate. Check the
TM
attempts to transmit a CAN packet. In this case you must connect and
Driver
Although not necessarily a software
TM
device. This flashing LED indicates a physical CAN
Doc. No. ER000060_00 Rev E1-
Page 12 of 12