Yamaha disklavier IV / Pro Series Maintenance Handbook - Page 29
Browse online or download pdf Maintenance Handbook for Musical Instrument Yamaha disklavier IV / Pro Series. Yamaha disklavier IV / Pro Series 36 pages.
9. Trouble shooting and error logs
Specifying the cause and first aid
CSP board is the center of the piano driving / sensing system, I/O center (DIO100) is the operation center.
PRC100/TRC100
Media Center
Power supply
1) Power supply related
2) Data communication related
3) Piano system related
4) Drive/sensor unit related of the piano system
--> Certain key does not function well - Playback problem --> keyboard calibration
5) I/O center related
--> AWM (piano), XG(playback only), AEM tone generators - post delivery check see 5-8.
--> Hard disk problem - Check red LEDs on the side of I/O center ( all stop blinking - Error )
Error log history
Not only error but also operation or
maintenance history will be stored
until 5,000 records maximum are in
the data base. 2,000 records out of
5,000 can be listed up sorting by
time or code.
E1 coded error must be fixed as the
first priority. E0 is just warning and
it is not necessary to be fixed.
The latest calibration history is also
available to see.
Operation center
I/O Center
Pedal drive/
Sensor
--> Check along the power turning procedure, see 5-11.
--> Check if the AC cord unplugged before the system stops completely
--> Wireless LAN connecting - check to see if LAN card is inserted for both PRC100 &
DIO100
--> Hang up the wireless communication due to the excess of sequential operation
- Reboot or reset wireless control, see 5-12-3.
--> Unit connections - Verify all connection check in the maintenance mode, see 6-4.
--> Turn power to standby mode from active and turn it on again to reset CSP board.
MHB23 MKIV/PRO DIOV1.05, SCV.1.01 PAGE.27
Piano center
CSP board
- Recording problem --> sensor calibration
- Silent (Quiet) play to find out key numbers which have
sensor problem.
Silent motor drive
Key / Hammer sensor
Key drive unit