Calian SatService sat-nms User Manual - Page 17

Browse online or download pdf User Manual for Controller Calian SatService sat-nms. Calian SatService sat-nms 17 pages. Power sensor

6 Specifications

RF Specification
Input frequency range (to be defined at order)
Input Connector
Input Return Loss
Input Power Measurement Range
Resolution of power level
Linearity failure
Averaging function selectable
M&C Interface Specification
Ethernet interface for M&C and user interface
User Interface
M&C Interface for remote monitoring & control
Summary fault / level alarm indication
Electrical and Mechanical Specification, Environmental
conditions
Supply Voltage, all stabilization necessary should be performed
on the board
Connector for 24V Supply and Alarm contact
Temperature range
Humidity
Compact Module
(C) 2020, SatService GmbH
5,8 to 6,6GHz (PSMC)
13,75 to 14,5GHz (PSMKu)
N male 50Ohm
> 16dB
+15 to -18dBm
0,01dB
+/-0,7dB
High, Low, Auto
10-Base-T
Via any Web Browser
Via http GET requests
Photo MOS Relay contact (120 V D/C,
100 mA)
22V to 28V unregulated DC
Binder Series 712 7PIN
5° to 50° C
up to 90% non condensing
185x60x35mm
www.satnms.com
PS-UM-2002 Page 16/16