SPARE PARTS
In the event of lost or damaged components, replacements are available
from Clarke Parts & Service. Please refer to the following parts list and
diagrams, quoting the Clarke part numbers:
• HT-CS4BRK-01 to 69
• HT-CS10BRK-01 to 69 or
• HT-CS10SBRK-01 to 69
FAULT FINDING
PROBLEM
Ram does not
operate when
handle is
pumped
Ram will not hold
load.
Ram reluctant to
lower when load
removed.
Ram will not
extend to full
range of stroke
Ram tries to tilt to
one side.
If any of these remedies fail to restore your equipment's performance, consult
your CLARKE dealer.
CAUSE
Release valve not
tightly closed.
Air trapped in
system
Release valve not
tightly closed.
Malfunction in
pump such as dirt
inside valve
mechanism.
Oil reservoir
overfilled.
Piston binding.
Low oil level.
Poor positioning of
the footing
SOLUTION
Firmly close the release valve.
Purge air from the system by
pumping the operating handle.
Firmly close the release valve.
Return pump to dealer for overhaul.
Drain oil to the correct level
Clean and lubricate moving parts.
Add hydraulic oil to the reservoir.
Stop work and reposition ram and
base, ensuring it is well supported
and as close to the perpendicular to
the repair as possible.
11