Clarke STRONG-ARM CSA10BB Operation & Maintenance Instructions Manual - Page 9

Browse online or download pdf Operation & Maintenance Instructions Manual for Power Tool Clarke STRONG-ARM CSA10BB. Clarke STRONG-ARM CSA10BB 17 pages. 10 tonne hydraulic bench press

Clarke STRONG-ARM CSA10BB Operation & Maintenance Instructions Manual

MAINTENANCE

• A visual inspection must be made before each use of the press, checking for
leaking hydraulic fluid and damaged, loose, or missing parts.
• Owners and/or users should be aware that repair of this equipment requires
specialised knowledge and facilities. It is recommended that a thorough
annual inspection of the press be made and that any defective parts be
replaced with genuine Clarke parts.
• Any press which appears to be damaged in any way, is found to be badly
worn, or operates abnormally SHOULD BE REMOVED FROM SERVICE until the
necessary repairs are made.
• If the press is not to be used for any length of time, store it with the ram piston
withdrawn and the operating handle in the lowered position to protect the
moving parts.
PERIODICALLY
• Check the press frame to make sure all bolts are tight and inspect for
cracked welds, bent, loose or missing parts.
• Check the hydraulic connections for leaks. Replace or properly repair any
damaged or leaking hydraulic components before using. In the event of
leaking seals, oil can be topped up via the filler plug at the end of the unit.
Oil should be level with the mark on the dipstick. If necessary top up with
CLARKE hydraulic oil, Part No 3050830. This task is carried out with the ram
fully retracted.
• If any rust is apparent it must be removed completely and the paint restored.
DE-COMMISSIONING THE PRODUCT
Should the product become completely unserviceable and require disposal,
draw off the oil into an approved container and dispose of the product and
the oil according to local regulations.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
9