Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS
ZGG 642
Width:
580 mm.
Depth:
510 mm.
CUT OUT DIMENSIONS
ZGG 642
Width:
550 mm.
Depth:
470 mm.
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
NOMINAL THERMAL
POWER kW
NOMINAL FLOW
RATE m
NOZZLE REFERENCE
NOMINAL THERMAL
POWER kW
NOMINAL FLOW
RATE
NOZZLE REFERENCE
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
Semi-rapid
Ultra-rapid
Aeration adjustment none
8
ZGG 782
680 mm.
510 mm.
ZGG 782
560 mm.
480 mm.
BURNER
ULTRA-RAPID
(triple crown)
POSITION
MAX
3.8
3
/h
0.362
146
1/100 mm
3.8
g/h
274
98
1/100 mm
28
32
56
Semi-rapid Burner
Heat Input
Auxiliary Burner
Heat Input
Ultra-rapid Burner (triple crown)
Heat Input
Gas supply
Appliance class
Appliance category
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
1.20
1.9
0.45
1.0
0.114
0.181
0.043
0.095
Adjust.
96
Adjust.
70
1.20
1.9
0.45
1.0
86
137
32.4
72
40
71
32
50
APPLIANCE CLASS: 3
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY:
Natural gas G20 / 20mbar
1.9 kW (6,483 BTU/HR)
1.0 kW (3,412 BTU/HR)
3.8 kW Natural Gas (12,966 BTU/HR)
3.8 kW L.P.G. (12,966 BTU/HR)
Natural gas G20 / 20mbar
3
II2H3+
(small)
MIN
0.33
0.031
Adjust.
0.33
23.8
28