Zanussi ZGL 62 Instruction Booklet - Page 8
Browse online or download pdf Instruction Booklet for Hob Zanussi ZGL 62. Zanussi ZGL 62 16 pages. Zanussi instruction gas hob zgl 62
Also for Zanussi ZGL 62: Instruction Booklet (16 pages)
Instructions for the Installer
Engineers technical data
Overall dimensions
Width:
580 mm
Depth:
500 mm
Cut out dimensions
Width:
550 mm
Depth:
470 mm
Supply connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V 50 Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
32
Rapid
40
Aeration adjustment none
8
BURNER
RAPID
(large)
POSITION
MAX
kW
3.0
m
/h
0.286
3
119
Adjust.
1/100 mm
kW
2.8
g/h
202
86
1/100 mm
Rear Left Burner
Heat Input
Front Left Burner
Heat Input
Rear Right Burner
Heat Input
Front Right Burner
Heat Input
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
0.65
2.0
0.45
1.0
0.062
0.190
0.043
0.095
96
Adjust.
70
0.65
2.0
0.45
1.0
47
144
32
72
40
71
32
50
APPLIANCE CLASS:
APPLIANCE CATEGORY:
APPLIANCE GAS SUPPLY:Natural gas G20/20 mbar
2.0 kW (6824 BTU/HR)
3.0 kW Natural gas (10236 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
2.0 kW (6824 BTU/HR)
1.0 kW (3412 BTU/HR)
(small)
MIN
0.33
0.031
Adjust.
0.33
24
28
(semi rapid)
(rapid)
(semi rapid)
(auxiliary)
3
II2H3+