Zanussi ZGLR 646 Operating And Installation Manual - Page 10

Browse online or download pdf Operating And Installation Manual for Hob Zanussi ZGLR 646. Zanussi ZGLR 646 11 pages.
Also for Zanussi ZGLR 646: Operating And Installation Manual (12 pages), Operating And Installation Manual (12 pages)

Zanussi ZGLR 646 Operating And Installation Manual

Building In

A = Auxiliary burner
SR = Semi-rapid burner
R = Rapid Burner
The hob can be inserted in a built-in kitchen unit whose
depth is between 550 and 600 mm. The hob dimensions
are shown in Fig. 7.
Installation and Assembly
The hob can be installed in a kitchen unit with an opening
for insertion whose dimensions are shown in Fig. 8.
The edge of the cut out must have a minimum distance
from the rear wall of 55 mm.
If there are side walls, or sides of the furniture unit near
the hob, the cut out edges must have a minimum
distance of 150 mm.
Carry out the building in of the hob as follows:
put the relevant sealings, supplied with the hob, on the
edges of the cut out, as shown in Fig. 9, taking care
that the sealings meet without overlapping;
place the hob in the cut out, taking care of its centring;
fix the hob with the relevant screws (Fig. 8). The
traction of the screws is able to trace the sealing, any
excess of which can then be easily removed.
The edge of the hob forms a double labyrinth seal which
provides a total guarantee against infiltration of liquids.
1 0
SR
R
SR
A
a) sealing
Fig. 7
a
Fig. 8