Zanussi ZCG560G User Manual - Page 16

Browse online or download pdf User Manual for Cookers Zanussi ZCG560G. Zanussi ZCG560G 20 pages. Zanussi zcg560g cooker user manual
Also for Zanussi ZCG560G: User Manual (20 pages)

Zanussi ZCG560G User Manual
– It does not make contact with sharp edges or
corners.
– You can easily examine it in order to check
its condition.
To preserve the flexible pipe, you must regularly
check if:
– It does not show cracks, cuts or burn marks
on the two ends and its length.
– The material is correctly elastic and not hard-
ened.
– The fastening clamps are not rusted.
– It is not expired.
If you can see one or more defects, do not re-
pair the pipe, but replace it.
Important! After installation is complete, use a
soapy solution and never a flame to see if you
sealed all the pipe fittings perfectly.
The gas supply ramp is on the rear side of the
control panel.
Warning! Before gas connection
close the primary valve of the gas
supply.
A
B C
E
D
Gas connection point (only one point is ap-
1
plicable for appliance)
Gasket
2
Adjustable connection
3
LPG pipe holder
4
Natural Gas pipe holder
5
The appliance is set to default gas, to
change the setting choose pipe holder
from the list. Always use the gasket sealing.
Adjustment to different types of gas
Warning! Let only an authorized person
do the adjustment to different types of gas.
16
This appliance is for operation with natural
gas.
With the correct injectors, you can also operate
it with liquid gas.
Warning! Before replacing the injectors,
make sure that the gas knobs are in the off
position. Let the appliance cool off fully. There
is a risk of injury.
Injectors replacement
Replace the nozzles when changing the gas
type.
1. Remove the pan supports.
2. Remove the caps and crowns of the burn-
er.
3. With a socket spanner 7 remove the injec-
tors and replace them with the ones which
are necessary for the type of gas you use.
4. To assemble the parts, do the same steps
in reverse.
5. Replace the rating label (it is near the gas
supply pipe) with the one for the new type
of gas supply. You can find this label in the
package supplied with the appliance.
If the supply gas pressure is changeable or dif-
ferent from the necessary pressure, you must fit
an applicable pressure adjuster on the gas sup-
ply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the control knob.
4. With a thin screwdriver, adjust the by-pass
screw position (A).
• If you change from natural gas to liquid gas,
fully tighten the adjustment screw in.
A