• The wire, which is coloured blue, must be
connected to the terminal, which is marked
with the letter N or coloured black.
• The wire, which is coloured brown, must be
connected to the terminal, which is marked
with the letter L or coloured red.
• Ensure that the cable does not become
trapped when pushing the appliance into
position.
If a moulded plug is fitted.
• In the event of replacing a fuse in the plug
supplied a 3 amp ASTA approved fuse to
B.S. 1362 must be fitted.
IMPORTANT!
The fuse cover must be refitted when changing
the fuse. In the event of losing the fuse cover
the plug must not be used until a replacement
fuse cover has been obtained and fitted.
Connecting to gas supply
• This appliance is designed to be installed
with an appliance flexible connection only.
• Supply piping should not be less than R
Connection is made to the Rc ½ (½" B.S.P.)
female threaded entry pipe located just
below the hob level on the rear left hand side
of the appliance.
IMPORTANT!
ONLY LIQUID SEALANTS TO BE USED
WHEN INLET GAS PIPE IS FITTED I.E.: DO
NOT USE P.T.F.E. SEALANT TAPE.
• Carry out a gas tightness test after
connecting to the gas supply.
• The gas bayonet connector must be fitted in
the shaded area indicated.
30
• Take into account that it must be possible to
pull the appliance forward sufficiently.
Ensure the hose does not become trapped
when pushing the appliance into position.
IMPORTANT!
FLEXIBLE TUBING USED MUST COMPLY
/8.
3
WITH BS.669 CURRENT EDITION.
Fitting the stability chain
It is recommended that if the appliance is to be
installed with a flexible supply pipe, a stability
chain be fitted and is available from your
supplier (see Important Safety Requirements).
These instructions should be read in conjunction
with any leaflet packed with the stability chain.
1.
Place the appliance in its intended position
and level appliance.
2.
Mark a position 100mm from the top of the
rear right hand corner.
3.
Measure down 150mm from this point.
This gives the position of the wall anchor
point for the stability chain.