Fault Finding

With considerate use, your CLARKE Air Compressor should provide you with long and
trouble free service. Routine checks should be made on both the electrical supply as well
as the compressed air lines and connections. If any fault appears, the reason for which is
not immediately obvious, please contact your local CLARKE Dealer.
PROBLEM
The compressor
stops and will not
start again.
The compressor does
not reach the set
pressure and
overheats easily.
Low Pressure

Technical Data

Model .................................................................. BANDIT
Maximum Air Pressure ....................................... 8 BAR - 116 PSI
Air Displacement ............................................... 4.5 CFM
Motor .................................................................. 1.25 HP
Voltage ............................................................... 230 VAC 50hZ 1pH
Motor Speed ...................................................... 2850RPM
Sound Power Level ............................................ 87dBL
Weight ................................................................. 15 kg (unpacked)
Part Number ....................................................... 3110243
Dimensions (mm) ............................................... 425x325x460mm
Duty Cycle ......................................................... 2 min ON, 2 min OFF**
**Duty Cycle...This is in respect of the compressor motor ONLY. If the motor runs
CONTINUOUSLY for more than 2 minutes, there is a danger of damage occuring.
Under these circumstances, it must be switched OFF for at least a 2 minute period.
Please note that the details and specifications contained herein are correct at the time of going to
print. However CLARKE International reserve the right to change specifications at any time without
prior notice. Always consult the machines data plate
PROBABLE CAUSE
Bad connections.
Thermal Overload has
intervened.
Motor windings burnt out.
Compressor head gasket
blown or valve broken.
Broken piston
Air Leak - safety Valve
Restricted air filter
Defective Check Valve
- 9 -
REMEDY
Check electrical connections.
Clean and tighten as necessary.
Switch off and wait at least 5
minutes before trying to restart
Contact your local dealer for a
replacement motor.
Contact your CLARKE dealer.
Replace Piston (contact your
CLARKE dealer)
Blip safety valve by pulling the pull ring. If
condition persists See your Clarke dealer
Clean air filter, or replace
See your Clarke dealer