OCCASIONALLY
In the event of leaking seals, oil can
be topped up via the filler plug on
the side of the pump. Oil should be
level with the bottom of the hole. If
necessary top up with CLARKE
hydraulic oil, Part No. 3050830. This
task is carried out with the ram fully
retracted. Further repairs should be
carried out by your Clarke dealer.
If any rust is apparent it must be
removed and the paint restored.
In the event of an airlock, air bubbles can be purged from the ram as follows;
1. Depress the release valve pedal.
2. Pump the actuating pedal several full strokes to eliminate any air bubbles.
Top up the hydraulic oil to the lower level of the filler plug with CLARKE
hydraulic oil, Part No. 3050830.

TROUBLESHOOTING

Problem
Pump will not work.
Pump will not produce
pressure.
Pump feels hesitant
under load.
Pump will not lower
completely.
Pump will not deliver
pressure.
Pump feels hesitant
under load.
Piston will not withdraw
completely.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
Probable Cause
Dirt on seals/worn valve
components.
Air-lock.
Pump has wrong low oil
level.
Pump seal could be
worn out.
Air-lock.
9
Remedy
Bleed pump or have unit
overhauled with new
seals by your dealer.
Open the release valve
and remove the oil filler
plug. Pump the actuat-
ing pedal a couple of full
strokes and close the
release valve. Replace
the filler plug.
Check oil level by
removing the filler plug
and topping up to the
correct level.
Have the seal replaced
by your Clarke dealer.
Release air by removing
the filler plug.