STOPPING THE COMPRESSOR

1. At the end of the day, stop the compressor in accordance with the
instructions in the engine manual, then open the drain cock.
2. Close the air outlet by sliding both valves inwards.
3. Operate the air tool trigger or operating lever etc., to ensure there is no
pressure in the air line, then disconnect airline and tool.
WARNING: DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO REMOVE
THE AIR TOOL OR DISCONNECT THE AIR HOSE UNTIL YOU ARE SATISFIED
THAT THE PRESSURE HAS BEEN RELIEVED.
4. Finally, close the drain cock.
5. Take care not to touch the engine or pump as they remain hot for some
time after use.