Aleko Victoria Series Installation Manual - Page 15

Browse online or download pdf Installation Manual for Accessories Aleko Victoria Series. Aleko Victoria Series 17 pages. Sizes 6.5x5 8x6.5 10x8
Also for Aleko Victoria Series: Installation Manual (20 pages), Instructions For Installation And Operation Manual (12 pages), Assembly Manual (14 pages)

Aleko Victoria Series Installation Manual
Correct operation
� REPAIR MANUAL
CASE OF MALFUNCTION
The awning does not work when
1
operated by the remote control.
When operated by remote control,
the awning does not work, although
2
you can hear the signal sound from
the remote control receiver.
The fabric is loose, even though the
3
awning is extended entirely.
4
The cassette can't close completely.
There is unwanted noise when
5
operating the awning.
When operated by a remote con-
trol, the indicative lamp does not
6
work and there is no signal from
the receiver.

Common mistakes

Wrong operation
REASON
1 .
There is no power supply.
2.
The residual current automatic
circuit breaker is turned to "off."
3.
The voltage is too low.
1 .
The remote receiver and motor
are switched or the wire from
the motor is disconnected.
2.
The motor switched off due to
the overheat protection.
The path length is incorrectly ad-
justed.
The connecting position between
the front bar and the front beam.
There is a loose screw.
1 .
The cell is exhausted.
2.
The cell is disconnected.
13
WARNING: When the front bar
touches the roller as shown in
the figure, don't try to make them
closer, otherwise the product
may be damaged.
REPAIR METHOD
1 .
Check the plug to see whether
it is properly connected.
2.
Call a professional to inspect.
3.
Call a professional to inspect
the voltage.
1 .
Check two places: fasten pins,
and the screws.
2. The motor will automatically
resume operation after approx-
imately 20 minutes.
Readjust the path length according
to the direction of the motor.
Adjust the position of the front
beam until the cassette is entirely
shut.
Check all screws to ensure that they
are tightly fastened.
1 .
Replace with a new cell.
2.
Reset the cell.