Alemite 7783-B4 Service Instructions Manual - Page 3

Browse online or download pdf Service Instructions Manual for Water Pump Alemite 7783-B4. Alemite 7783-B4 10 pages. Low pressure fluid lubricant pumps

Alemite 7783-B4 Service Instructions Manual
Fluid Lubricant Pump
3 Check all hoses for weak or worn conditions prior to daily work op-
erations, making certain that all connections and fittings are secure.
4 Never point dispensing device at oneself or at any other person: ac-
cidental discharge of pressure will result in serious injury.
5 Release all pressures within the system before attempting to re-
move or service any components in the system.
6 Be sure to read all instructions and any other explanatory material
carefully and thoroughly, before attempting to assemble, disassem-
ble, or operate the system.

INSTALLATION

NOTE: Remove all shipping seals from air motor 323440-4 and
pump tube assembly.
1 Thread male adapter 328037 into 3/4" air inlet of air motor
(Figure 2).
2 Thread air coupler 328031 onto facility air hose.
3 If unit is equipped with eyebolt, remove pipe plug from top of air
motor and replace with eyebolt (Figure 2).
4 If unit is to be used with an optional cover assembly, perform the
following steps:
NOTE: It may be desirable to lift pump (by eyelet) with a hoist for
ease in installing cover assembly onto pump.
4.1 Slide cover over pump tube and align four (4) holes of cover
with holes on underside of air motor assembly.
4.2 Secure cover using four (4) stop nuts and four (4) screws
(supplied).
4.3 Install three (3) thumb screws into openings on side of cover.
5 Install and secure pump into drum, tank, or suction pipe.
6 Connect material hose (not supplied) to 1/2" material outlet of air
motor assembly.
7 Connect air coupler 328031 of facility air hose to male adapter
328037 in air motor assembly.
Noise level test
Distance
60 psi (4,1 bar)
3 ft. (0,9 m)
95 dB
Alemite LLC
100 psi (6,8bar)
95 dB
3

OPERATION

CAUTION
If dispensing devise is used with the system, never point it at
oneself or any other person. Accidental discharge of material
may result in serious injury.
1 Check entire system (fittings, hoses, connections, etc.) for leaks or
signs of wear.
IMPORTANT: Extra care should be taken to protect material lines
from damage or wear. Do not kick hose or place near sharp moving
objects. ACCIDENTAL DISCHARGE OF MATERIAL MAY RESULT
IN SERIOUS INJURY.
2 Gradually turn on air supply while checking for leaks in the system.
3 Adjust air pressure to receive desired material pressure.
NOTE: The use of an air regulator (not supplied) is recommended to
determine and control air pressure.
CAUTION
Maximum operational air pressure is 200 psi. DO NOT exceed
this limit.
4 If no leaks are present and system stalls out, pump is now ready for
use.
CAUTION
DO NOT operate unit if condition of any parts are in question.

MAINTENANCE

Do the following periodically:
1 Check for any damage to material or air supply lines.
2 Check all connections and fittings for tightness.
3 Check level of material in drum.
NOTE: Do not allow pump to run "dry" at any time.
SER 7783-A4
Revision (3-15)