Clarke 7230693 Operation & Maintenance Instructions Manual - Page 8
Browse online or download pdf Operation & Maintenance Instructions Manual for Water Pump Clarke 7230693. Clarke 7230693 13 pages. 250w puddle pump with auto sensor
TROUBLESHOOTING
PROBLEM
PUMP WILL
NOT START
PUMP WILL
START BUT NOT
PUMP
PUMP WILL
NOT STOP
PUMP STOPS
RUNNING
If this does not solve your problem, please contact the Clarke service
department.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
SOLUTION
1. Make sure that the power is switched on.
2. Check fuse (consult an electrician if in doubt).
3. If an extension lead is fitted, check connections (consult
an electrician if in doubt).
4. Internal thermal cut-out has not re-set. Leave for 5-10
minutes and try again.
5. The impeller may be jammed. Disconnect from the mains
supply and remove any objects that may be obstructing
the impeller.
6. Water level too low. - Try using the pump in manual
operation mode.
7. If the pump still fails to start, consult your CLARKE dealer
for advice.
1. Check that the inlet is not blocked.
2. Check that the outlet is not clogged or obstructed.
3. The head may be too great, i.e. you are trying to lift the
water too great a distance for the pump to cope with.
("Specifications" on page 7).
4. Air bubble in the pump, produced during immersion.
immerse the pump again, at an angle, and shake it whilst
lowering to remove any air trapped in the system.
5. Impeller may be damaged - Consult your CLARKE dealer.
1. Sensor may be faulty. Consult your CLARKE dealer for
advice.
1. Thermal overload has operated. Leave for 5-10 minutes
and try again.
2. Pump has run dry, or auto sensor has cut in.
3. A foreign object has jammed the impeller.
8