Clarke CWP200 Operation & Maintenance Instructions Manual - Page 5
Browse online or download pdf Operation & Maintenance Instructions Manual for Water Pump Clarke CWP200. Clarke CWP200 13 pages. Submersible clean water pump
9. NEVER insert your fingers into the pump whilst it is connected to the mains.
10. Keep the pump clear of any sediment by standing it on a platform or brick
or suspending it at a suitable depth.
11. Do not use the pump if the water is liable to freeze, as this can cause
damage to the pump. Remove the pump from the water and store it in a
frost free location.
ELECTRICAL CONNECTIONS
WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS
SUPPLY.
Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply
through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.
If the plug has to be changed because it is not suitable for your socket, or
because of damage, it must be removed and a replacement fitted, following
the wiring instructions shown below. The old plug must be discarded safely, as
insertion into a power socket could cause an electrical hazard
WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL
If the colours of the wires in the power cable do not agree with the markings
on the plug.
• Connect the BLUE wire
to the terminal
marked N.
• Connect the BROWN
wire to the terminal
marked L.
• Connect the YELLOW
AND GREEN wire to
the terminal marked E
or
.
AN APPROVED RESIDUAL CURRENT DEVICE (RCD) WHICH HAS A TRIPPING
CURRENT OF LESS THAN 30 mA MUST BE USED.
If you are not sure, consult a qualified electrician. DO NOT try to do any
repairs.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
BROWN = LIVE
YELLOW AND GREEN = EARTH
Plug must be BS1363/A approved.
Earth
(Green and
Yellow)
Neutral
(Blue)
Ensure that the outer sheath of
the cable is firmly held by the clamp
5
.
Always fit
a 13 Amp
fuse.
Live
(Brown)