ELECTRICAL CONNECTIONS

The mains lead should be connected to a standard 230Volt (50Hz) electrical supply
through an approved 13Amp BS 1363 plug or a suitably fused isolator switch. We
recommend that the pump be connected via a Residual Current Device (RCD).
If used for draining swimming pools or ponds, it is mandatory that the
pump be fitted with a Residual Current Device (RCD), with a rated
If the pump is to be connected to an outdoor electrical supply, make sure that
both the plug and the socket are of a BS approved waterproof design.
In the event that the pump is hard wired into the electrical system, it must be
carried out in accordance with IEE regulations.
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in the mains lead are coloured in accordance with the
following code:
As the colours of the flexible cord of this appliance may not correspond with the
coloured markings identifying terminals in your plug proceed as follows:
Connect GREEN & YELLOW cord to plug terminal marked with a letter "E" or
Earth symbol "
Connect BROWN cord to terminal marked with a letter "L" or coloured RED
Connect BLUE cord to terminal marked with a letter "N" or coloured BLACK
FUSE RATING
The fuse in the plug for this appliance must be rated at 13 amps.
If this appliance is fitted with a plug which is moulded onto the electric cable (i.e.
non-rewirable) please note:
1.
The plug must be thrown away if it is cut from the electric cable. There is a
danger of electric shock if it is subsequently inserted into a socket outlet.
2.
Never use the plug without the fuse cover fitted.
3.
Should you wish to replace a detachable fuse carrier, ensure that the correct
replacement is used (as indicated by marking or colour code).
4.
Replacement fuse covers can be obtained from your local dealer or most
electrical outlets
5.
The fuse in the plug must be replaced with one of the same rating (13 amps)
and this replacement must be approved to BS1362.
residual operating current of no greater 30mA.
Green & Yellow
Blue
Brown
" or coloured GREEN or GREEN & YELLOW.
I MPORTANT:
-
Earth
-
Neutral
-
Live
4