SPECIFICATIONS
Motor .......................................................................... 230V 50Hz 1ph
Motor Rating (Nominal -Output) .............................. 927W
Input Current .............................................................. 4.13Amps
Fuse Rating ................................................................ 13 Amps
Outlet Connection .................................................... 2" BSP Female
Head Max. ................................................................. 7.4m
Max. Submersion Depth ........................................... 7.4m
Max. Capacity .......................................................... 333 l/min
Max. Water Temperature .......................................... 50°C
Weight (unpacked) ................................................... 11.7kg
Cable Length ............................................................. 10m
Part No. ...................................................................... 7230091
WARNING!
Connection to the mains supply MUST be made well clear of the water, or, if in close
proximity, it must be completely waterproofed and secured to prevent the possibility
of it coming into contact with water. If necessary consult a qualified technician.
A - 203mm
B - 170mm
C - 2" BSP
Fig.2
D - 172mm
E - 98mm
H - 492mm